First run

2

FIrST run

After turning the power on at the main power panel, the 

top-side panel display will go through specific sequences. 

This sequence displays a variety of information regarding 

the configuration of the minipool.

PrIMIng MoDE 

This procedure lasts 4-5 minutes

, during which the heat-

ing is deactivated to prevent any overheating in case of 

low or non-existent flow.

You can exit the mode manually even before the end of 

the 4-5 minutes by pressing one of the temperature keys 

+ or -. In this case the display will show:

READY

RANGE

o

READY

RANGE

Regardless of whether you wait for the priming to finish 

or exit manually before it is completed, the system will 

automatically return to heating and filtering normally only 

when the process has completed.

During the priming procedure it is possible to activate

 

the 

pumps

 pressing the “Jet” key 

If your minipool has a 

recirculation pump

, it is possible 

to activate it by pressing the “light” key 

 during the 

priming process.

PrIMIng ThE PuMPS

As soon as the control panel display lights up, press the 

“Jet” key 

 once to activate pump 1 at low speed 

and press it a second time to increase the speed.

If you have a second pump, press the “Jet2” 

 key 

to activate it. The pumps work at high speed to facilitate 

priming. 

If the pumps are not primed after two minutes and the 

water does not come out, turn off the pumps and repeat 

the process. Switching off and restarting will start a new 

pump priming process. Sometimes momentarily turning 

the pump off and on will help it to prime. Do not repeat 

the operation more than 5 times. If the pumps cannot be 

primed, switch off completely and call a Service Centre.

Main page

heater LED on

LED - chromotherapy on

LED - pump 1 on 

(jets 1)

LED - pump 2 on 

(jets 2)

Important: It is not allowed to operate a pump without the 

priming process being completed. Doing so may cause 

damage to the pump and cause the system to energize 

the heater and go into an overheat condition.

Exiting Priming Mode

It is possible to manually exit the priming mode by press-

ing one of the temperature keys, otherwise the priming 

process ends automatically after 4-5 minutes. Be sure that 

the pump(s) have been primed by this time.

When the system exits priming mode, the display shows 

the following.

Warm

Jets(1)

Jets(2)

menu/

select

Cool

Light

Summary of Contents for Muse GP

Page 1: ...Installation manual Muse GP minipool...

Page 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Page 3: ...___ 8 3 CONNECTIONS REQUIRED__________________________________________________________ 9 4 WATER SUPPLY_____________________________________________________________________ 12 CHARACTERISTICS OF THE W...

Page 4: ...at do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not place objects insid...

Page 5: ...on port measuring at least 50 cm wide has been prepared on all sides of the minipool The connections to the electrical grid have been made in compliance with current regulations in force in the countr...

Page 6: ...ys to reach the desired place of installation Movement must be carried out using personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precau tions for those in...

Page 7: ...into the prepared space If it was not possible to provide a technical inspec tion port on all sides of the minipool a pneu matic lift is available optional to be request ed from the Manufacturer in o...

Page 8: ...r Before installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer qualified and...

Page 9: ...mbing connection to an exchanger optional if provided see following page The following pages will provide detailed explanations of how to perform these preparations Examples of outdoor indoor minipool...

Page 10: ...1 BL2 HTR Cromo 230V EVc EVs EVclv J49 J48 230V heater exchanger control cable C switch recommended OUT outgoing cold water P circulator not supplied PR recirculation pump S exchanger not supplied The...

Page 11: ...nical inspection port IN water inlet OUT water outlet 230V IN PR F C CP 230V circulator control cable OUT water outlet IN water inlet PR recirculation pump F filter C control unit Inlet connection 1 1...

Page 12: ...ariations Water pH What is pH The pH is a chemical parameter that gives an idea of the acidity or basicity of the water It can assume values between 0 and 14 By definition water is considered neutral...

Page 13: ...he instructions provided by the manufacturer of the cleaning product used Paper filters should be mounted when they are com pletely dry 5 2 1 4 3 6 emptying the minipool CLICK 1 2 4 3 Emptying takes p...

Page 14: ...ty equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control unit s power supply cable must be of the H05 type with thr...

Page 15: ...e minipool for a distance of at least 60 cm and a height of 230 cm Make sure that The minipool is level and stable Electrical connections are made correctly in accordance with local and national codes...

Page 16: ...the quality of the water supply This is very important for the well being of the users and for the long life of the minipool For more information see chapter Characteristics of the water supply on pag...

Page 17: ...ntrol panel display lights up press the Jet key once to activate pump 1 at low speed and press it a second time to increase the speed If you have a second pump press the Jet2 key to activate it The pu...

Page 18: ...ndicates that it is necessary to wait before knowing the water temperature in order for it to be detected correctly in fact the pump dedicated to water circulation must have been in operation for at l...

Page 19: ...ption No water in the heater All minipool functions are disabled After solving the problem remove and restore the power to initialize the water heating procedure See the Water flow problems section Th...

Page 20: ...description The sensor connected to the temperature survey or the circuit sensor do not work Solutions Contact Technical Service VARIOUS TYPES OF MESSAGES DISPLAY SCREEN DESCRIPTION OF SIGNALS AND PO...

Page 21: ...Solutions Contact Technical Service Configuration error The minipool doesn t start Solutions Contact Technical Service GFCI fault The system is not connected to the GFCI M036 Problem description ONLY...

Page 22: ...22 EN Muse GP minipool Mount the wood or laminate resin panels as shown in the figures below Decorative panels 2 3 1 1 3 2...

Page 23: ...is especially useful if the minipool is installed outdoors In this case it might be useful to anchor it with lashing straps in order to prevent the wind from moving it or blowing it off Covering Maxim...

Page 24: ...www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres it Muse GP installation Edition 10 2020...

Reviews: