17
EN
M
use GP
minipool
JETS 1
JETS 2
BLOWER
WARM
COOL
LIGHT
First run
2
FIrST run
After turning the power on at the main power panel, the
top-side panel display will go through specific sequences.
This sequence displays a variety of information regarding
the configuration of the minipool.
PrIMIng MoDE
This procedure lasts 4-5 minutes
, during which the heat-
ing is deactivated to prevent any overheating in case of
low or non-existent flow.
You can exit the mode manually even before the end of
the 4-5 minutes by pressing one of the temperature keys
+ or -. In this case the display will show:
READY
RANGE
o
READY
RANGE
Regardless of whether you wait for the priming to finish
or exit manually before it is completed, the system will
automatically return to heating and filtering normally only
when the process has completed.
During the priming procedure it is possible to activate
the
pumps
pressing the “Jet” key
.
If your minipool has a
recirculation pump
, it is possible
to activate it by pressing the “light” key
during the
priming process.
PrIMIng ThE PuMPS
As soon as the control panel display lights up, press the
“Jet” key
once to activate pump 1 at low speed
and press it a second time to increase the speed.
If you have a second pump, press the “Jet2”
key
to activate it. The pumps work at high speed to facilitate
priming.
If the pumps are not primed after two minutes and the
water does not come out, turn off the pumps and repeat
the process. Switching off and restarting will start a new
pump priming process. Sometimes momentarily turning
the pump off and on will help it to prime. Do not repeat
the operation more than 5 times. If the pumps cannot be
primed, switch off completely and call a Service Centre.
Main page
heater LED on
LED - chromotherapy on
LED - pump 1 on
(jets 1)
LED - pump 2 on
(jets 2)
Important: It is not allowed to operate a pump without the
priming process being completed. Doing so may cause
damage to the pump and cause the system to energize
the heater and go into an overheat condition.
Exiting Priming Mode
It is possible to manually exit the priming mode by press-
ing one of the temperature keys, otherwise the priming
process ends automatically after 4-5 minutes. Be sure that
the pump(s) have been primed by this time.
When the system exits priming mode, the display shows
the following.
Warm
Jets(1)
Jets(2)
menu/
select
Cool
Light