Cluster Mode
Cluster ID
Generated ID of the cluster for master/slave mode.
Cluster Size
Number of engines in this cluster.
Device Mode
Master or Slave n/m (n of m).
Advanced Setup
Lock Settings
Checkmark, set by default, avoids changes for DMX
and RDM by chance.
BRK Length
Break signal length in µs for the DMX protocol.
MAB Length
Mark after break length in µs for the DMX protocol.
BRK Length RDM
Break length in µs for the RDM protocol.
MAB Length RDM
Mark after break length in µs for the RDM protocol.
RDM Switch Time
The RDM Tx to Rx length in in µs.
BRK Length
Break length for e:pix protocol (not used).
MAB Length
Mark after break length for e:pix protocol (not used).
Do not modify the Advanced Settings, if you are not fully aware of the results.
Close the Network Configuration Dialogue, the changes will be transferred to the
Butler S2. You can now integrate the Butler S2 to the Programmer for DMX output
or show upload.
Execute the Device Manager dialogue of the Programmer by clicking the smart-
phone symbol in the top menu.