Installation
(for qualified installers only)
39
© Travis Industries
4070620
100-01199_000
Installation Example - Build-Out (Dog-House) with Hor. Termination
•
The framing, facing, and other building materials depicted below are for example only. Refer to local
building codes for framing, facing, and insulating requirements in your area.
Side View
Top View
See “Vent Termination”
for full requirements.
4” Section*
Firestop
NOTE FOR 2 x 4 EXTERIOR WALLS:
When installed with a 2x4 exterior wall, the
termination may not fit flush against the exterior
wall. You may wish to place framing around the
termination to fill the gap.
SIDE OF FIREPLACE
Horizontal Termination*
* Travis Ind. MIn. Vent Kit (SKU 98900168)
Includes a 4” section and horizontal termination.
Drywall
Optional Tile
NOTE
: If required to use drywall inside
the firebox enclosure, make sure to alter
the framing accordingly.
NOTE
:
In colder climates the fireplace may
require an insulated enclosure.
Insulation
Drywall
Optional Tile
Vapor
Barrier
NOTE
:
1/2” Clearance to sides
and back of fireplace.
The cap overlaps the exterior
siding by 1/16” - you may wish to
make a flashing for this area.
See “Vent Termination”
for full requirements.
The cap overlaps the exterior
siding by 1.6mm you may wish to
make a flashing for this area.
Includes a 100mm section and horizontal termination.
13mm Clearance to sides
and back of fireplace.
NOTE FOR 50mm x 100mm EXTERIOR WALLS:
When installed with a 50mm x 100mm
exterior wall, the termination may not fit
flush against the exterior wall. You may
wish to place framing around the
termination to fill the gap.
100mm Section*