Installation
(for qualified installers only)
27
© Travis Industries
4070620
100-01199_000
Top Vent Configuration with Horizontal Termination
•
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
•
Up to four elbows (45° or 90°) may be used.
•
Use 205mm diameter vent and the Amerivent Cowl (4DHC)
•
Only one horizontal elbow may be used.
5 feet
0 feet
0 feet
5 feet
0 feet
20 feet
20 feet
5 feet
10 feet
5 feet
10 feet
0 feet
15 feet
20' (max)
10 feet
15 feet
15 feet
20' (max)
10 feet
15 feet
21' (max)
21' (max)
Exhaust Restrictor # 6
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 2
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
This is considered a
vertical elbow
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
H2
6m (ma
x
)
4.5m
3m
1.5m
0m
4.5m
3m
1.5m
0m
6m (ma
x
)
4.5m
3m
1.5m
6m
6.4m (max)
4.5m
3m
1.5m
6m
6.4m (max)
0m
0m
This is considered a horizontal
elbow (it does not matter
whether it turns right or left). It
may be a 90° or 45° elbow.