![Travis Industries DVS EF Fireplace Owner'S Manual Download Page 8](http://html1.mh-extra.com/html/travis-industries/dvs-ef-fireplace/dvs-ef-fireplace_owners-manual_1154093008.webp)
8
Installation
(for qualified installers only)
© Travis Industries
4041213
1 0 0 - 0 1 1 5 2
Fireplace Placement Requirements
Setting Up the Standoffs
Standoff
a
Replace the screw to
secure the standoff.
Bend the standofff in
the sequence shown.
1/4" Nutdriver
Remove the screw
below the standoff.
b
1
2
3
c
The standoffs are shipped in the flat position. Make sure to follow the instructions
below before installing the fireplace.
AFTER
BEFORE
WARNING
:
Failure to set up the standoffs will result in an extreme fire hazard.
Minimum Framing Dimensions
-
A 1/2" clearance is required along
the sides and back of the fireplace.
The 1/2" stand-offs on the sides
and 6-1/4" stand-offs on the top of
the fireplace are designed to
separate the fireplace from the
framing members. These stand-
offs may contact the framing
members but no material may be
placed between the stand-offs.
-
Fireplace must be installed on a
level surface capable of
supporting the fireplace and vent
-
Fireplace must be placed directly
on wood or non-combustible
surface (not on linoleum or
carpet)
-
This heater may be placed in a
bedroom. Please be aware of
the large amount of heat this
appliance produces when
determining a location.
Gas Line (the inlet is 7-3/4" behind the
framing and 2-5/8" above the base of the
fireplace (see "Gas Line Connection" for
details).
37-1/4"
19-5/8"
35"
Route the electrical line (and optional
thermostat or remote control wire) to
the right of the fireplace.
NOTE: when venting to the rear, allow a
min. 8-5/8" gap centered behind the
fireplace (for the vent and wall thimble).
36" From Base of Fireplace.
NOTE: when using an elbow off the top of the
fireplace, allow for a 2" clearance above the
vent (1" to the sides and bottom).
Clearances
•
When installed, walls in front of the fireplace must be a minimum 6" to the side of the faceplate.
•
Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.
•
Fireplace must be placed so the vents below and above the glass do not become blocked