![Travis Industries DVS EF Fireplace Owner'S Manual Download Page 41](http://html1.mh-extra.com/html/travis-industries/dvs-ef-fireplace/dvs-ef-fireplace_owners-manual_1154093041.webp)
Optional Equipment
(for qualified installers only)
4 1
© Travis Industries
4041213
1 0 0 - 0 1 1 5 2
9
Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator. NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
Place the LP
label on the base
of the fireplace
near the gas
control valve.
d
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Remove and discard the
regulator, diaphram, spring
and center post.
a
b
Slotted
Screwdriver
(or T-20 Torx)
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
c
Slotted
Screwdriver
(or T-20 Torx)
1 0
Make the gas line connection, start the heater and thoroughly leak-test all gas connections and the
regulator. Check the pilot. Adjust if necessary.
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.