38 Installation
(for qualified installers only)
© Travis Industries
4090501
100-01226_000
Thick Facing with Fireplace Xtrordinair (FPX) Arched Faces
The following illustration shows facing considerations for those fireplaces utilizing FPX arched faces.
The facing must be non-combustible and over 1" (25mm) in depth.
The Fireplace Xtrordinair 864
Masonry Template is
recommended for masonry
installation (sku 98500688). The
template helps locate and
support the masonry as it being
installed.
Masonry Line
Hearth Line
Drywall
Floor-Mounted Fireplaces or Raised Hearths:
Build the hearth 1" (25mm) maximum above the
base of the fireplace. The fireplace may be
raised to accommodate thicker hearth materials.
Raised Fireplaces:
Masonry is installed 1" (25mm) maximum
above the base of the fireplace.
FRONT VIEW
35-3/4"
908mm
1"
41"
1041mm
5"
127mm
45-1/2" (1156mm) Radius
Before installing masonry, install
the FPX Face Upgrade Kit
(98500686). This covers the
upper corners.
Fireplace
Drywall
Framing
Nailing Bracket
Masonry
TOP VIEW
Face