1 4
Installation
(for qualified installers only)
© Travis Industries
4080207
100-01185_000
Fireplace Placement Requirements
•
The fireplace requires a 1/2" clearance from the angled sides and back of the fireplace to the framing
members. No material (insulation, framing, etc.) may be placed into this area.
The stand-offs (and
nailing brackets) may contact the framing members but no material may be placed into this
area.
•
Fireplace must be installed on a level surface capable of supporting the fireplace and vent.
•
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet).
•
This heater may be placed in a bedroom.
Clearances
•
Walls in front of the fireplace must be a minimum 1" to the side of the face.
•
Due to the high temperature, the heater should be located out of traffic and away from furniture and
draperies.
•
Fireplace must be placed so the vents below and above the glass do not become blocked.
Raised Fireplaces
NOTE:
Looking Glass and Wilmington Faces require a raised fireplace - see "Dimensions" for
details.
•
The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
(95 Lbs.) and vent.
Raised
Platform
Optional Hearth
Minimum
57"
Ceiling
Min. Enclosure Height
Top Vent = 48"
Rear Vent = 34-1/4"