4 8
Optional Equipment
(for qualified installers only)
© Travis Industries
4080207
100-01185_000
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
off the pilot
assembly.
5/32" Hex
Use a hex wrench to
unscrew the orifice.
Remove the orifice and replace with the LP orifice. Screw the
orifice all the way in and replace the pilot hood.
LP (Propane) Orifice
Orifice Identification:
NG (Natural Gas) Orifice
35
62
35
a
b
c
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
5
Replace the firebox
components. Install
the logs and embers.
Replace the glass.
6
Remove the regulator
from the front of the gas
control valve. Replace
with the propane
regulator, using the new
gasket and screws
included with the
regulator. NOTE: Leak
test this area after
the heater is
installed, gas is
connected, and the
main burner is lit.
Place the LP label on top of
the control cover near the gas
control valve.
d
Remove and discard the three
screws using a Torx T-20.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Remove and discard the
regulator, diaphram, spring
and center post.
a
b
Slotted
Screwdriver
(or T-20 Torx)
Install the LP regulator. Use the screws
included with the LP regulator. Tighten to
approximately 25 Lbs. torque.
c
Slotted
Screwdriver
(or T-20 Torx)