E M I T T - A S L F E A T U R E S
8
Crepitus
The EMITT-ASL’s upper left hip features a simulated crepitus (crackling) to cue for
a crushed pelvis.
Cautions and Care
The EMITT-ASL unit is water resistant, but not waterproof. Avoid direct water
contact with the battery compartment, bone end, and penis area. When washing
EMITT-ASL, use only water. Never use ink or marker to write on EMITT-ASL.
Doing so can cause damage to EMITT-ASL’s surface during removal.
When washing EMITT-ASL, use caution to prevent water from entering the
mechanical and electrical areas of the unit – the battery compartment should be closed
and secured before cleaning. Always use gentle pressure and avoid vigorous
scrubbing of the legs as this may affect the skin surface.
Often in live training scenarios, the EMITT-ASL’s simulated blood may come into
contact with a user’s clothes. To reduce the risk of staining, simulated blood should
be treated with detergent and be washed out of clothes within 24 hours of exposure.
Materials
The internal structure of the EMITT-ASL’s lower unit is composed of a heavy-duty
anodized aluminum yoke, surrounded by a rugged core, and layered with realistic
silicone-based skin. This construction results in a high-fidelity look and feel with
exceptional durability that allows the EMITT-ASL to be carried or dragged on many
surfaces such as outdoors or various flooring commonly found in buildings. Though
highly ruggedized, do not subject the EMITT-ASL to severely damaging conditions;
users must treat EMITT-ASL as they would care for a human patient. Failure to do
so can void the EMITT-ASL limited warranty.
The structure and joints do not require lubrication of any kind so do not attempt to
lubricate the EMITT-ASL.
Bleeding System
ALLERGY WARNING:
The tubing used in the EMITT-ASL’s
bleeding system is surgical quality and contains latex. A small portion
of the tubing is exposed externally at hemorrhage points within the
wounds. Individuals with latex allergies or sensitivities should use
proper precautions before operating, treating, or attempting to repair the
unit.
EMITT-ASL provides realistic physiological response to treatment. During training
exercises, proper wound packing with applied pressure combined with the
application of tourniquets or pressure at pressure points will occlude bleeding. The
Summary of Contents for EMITT-ASL
Page 2: ... Copyright 2020 TraumaFX Solutions Rev_Q4_2020_TSR ...
Page 24: ...G E T T I N G S T A R T E D 19 Figure 24 ...
Page 37: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 32 Blood Paste SDS ...
Page 38: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 33 ...
Page 39: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 34 ...
Page 40: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 35 Blood Powder ...
Page 41: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 36 ...
Page 42: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 37 ...
Page 43: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 38 ...
Page 44: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 39 ...
Page 45: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 40 ...
Page 46: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 41 ...
Page 47: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 42 Lithium Battery SDS ...
Page 48: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 43 ...
Page 49: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 44 ...
Page 50: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 45 ...
Page 51: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 46 ...
Page 52: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 47 ...
Page 53: ...A P P E N D I X B S A F E T Y D A T A S H E E T S 48 ...