III. e - CORD & PLUG:
Most self-contained models are supplied with a cord &
plug attached.  It is shipped coiled at the top of the cabi-
net, secured by a nylon strip.  For your safety and pro-
tection, all units supplied with a cord and plug include a
special three-prong grounding plug on the ser-
vice cord. Select only a dedicated electrical outlet with
grounding plug for power source.  NOTE: Do not under
any circumstances, cut or remove the round grounding
prong from the plug, or use an extension cord.
III. f - POWER SUPPLY:
The supply voltage should be checked prior to connec-
tion to be certain that proper voltage for the cabinet wir-
ing is available (refer to the serial tag to determine cor-
rect unit voltage).  Make connections in accordance with
local electrical codes.  Use qualified electricians.
Use of a separate, dedicated circuit is required.  Size
wiring to handle indicated load and provide necessary
overcurrent protector in circuit (see amperage require-
ments on the unit

s serial tag).

III. g - WIRING DIAGRAM:
Refer to the wiring diagram for any service work per-
formed on the unit.  Should you require one, please con-
tact Traulsen Service at (800) 825-8220, and provide the
model and serial number of the unit involved.
III. h - CLEARANCE:
In order to assure optimum performance, the condens-
ing unit of your Traulsen unit MUST have an adequate
supply of air for cooling purposes.  Therefore, the oper-
ating location must either have a minimum of 12

 clear-

ance overhead of the condensing unit or allow for unre-
stricted air flow at the back of the unit.  Clearance of at
least 12

 above is required in order to perform certain

maintenance tasks.

IV. OPERATION

IV. a - EVEN-THAW OVERVIEW:
The 

Even-Thaw

  refrigerator was specially designed

to thaw frozen food product under safe, temperature
controlled conditions.  It is not intended as a storage
refrigerator.
NOTE: USING THIS REFRIGERATOR FOR STORAGE OF
UNCOVERED PRODUCT IS NOT RECOMMENDED.
IV. b - EXPECTED PERFORMANCE:
The Traulsen Even-Thaw refrigerator is designed to thaw a
full load of frozen food product (see BATCH LOADING for
guidelines) in approximately 18 to 24 hours.   However, be
aware that actual thawing times will vary depending upon
a number of variables, such as product type, product pack-
aging, density, spacing, etc.  Please note that some other
loading variables, such as product location, are not impor-
tant to thawing and do not effect thaw cycle duration.

IV. c - EVEN THAW OPERATION:
The Traulsen Even-Thaw cabinet is a refrigerator, with two
important additional features: 1) the ability to introduce
small amounts of heat into the cabinet, and 2) increased
air flow, indicated by the presence of blowers mounted be-
hind the mullion.
The Even-Thaw refrigerator operates continually, the intro-
duction of frozen product lowers the cabinet temperature
below the heater setpoint temperature (37

°

F).  This prompts

the refrigeration system to turn OFF, and the heaters to turn
ON.  Anytime the cabinet air temperature is below the heater
setpoint temperature, additional heat is added.  Heater op-
eration is controlled proportionally, i.e. the colder the cabi-
net temperature, the longer the heaters remain in opera-
tion.  When the cabinet air temperature reaches above the
heater setpoint temperature, the heaters turn OFF.
When the cabinet air temperature reaches the upper refrig-
erator setpoint temperature (40

°

F), the refrigeration cycle

is initiated.  As long as product does not lower the cabinet
temperature below the lower refrigeration setpoint tempera-
ture (37

°

F), the cabinet will continue to cycle between 38

°

F

and 40

°

F.   Upon completion of a thaw cycle, the thawed

product should then be removed from the Even-Thaw cabi-
net and placed in a dedicated storage refrigerator.
IV. d - BATCH LOADING:
The Even-Thaw model can accommmodate any size partial
load, or up to twenty eight (28) 18

 x 26

 pans of product.

Use of aluminum pans is highly recommended.  Product
should be placed on pans in one layer only to allow for
proper air flow.
When completely loaded with frozen product (at approxi-
mately -5

°

F), the interior cabinet air temperature will begin

to drop and approach the product temperature as a result.
When this occurs the heaters begin operation in order to
return the cabinet temperature back up to the heater
setpoint temperature (37

°

F).  This portion of the thaw cycle

may take place for approximately 8 to 12 hours.  With a full
product load the interior cabinet temperature should re-
main at or below 37

°

F for approximately 8 to 12 hours of

the expected 18-24 hour total thaw cycle time.
IV. e - PROCESS LOADING:
If the cabinet is unloaded as needed and replaced with
frozen product, the average cabinet temperatures remain
higher.  A fully loaded cabinet with the refrigeration sys-
tem cycling from 38

°

F to 40

°

F thaws product faster than

one maintaining operation at below 32

°

F air temperatures

for several hours.
IV. f - INTERIOR ARRANGEMENTS:
Each reach-in Even-Thaw model includes 14 pairs of #1 tray
slides (16 gauge stainless steel angle type) for bottom sup-
port of either: (1) 18

 x 26

 pan per pair of tray slides or (2)

14

 x 18

 pans per pair of tray slides, per section.

-3-

III. INSTALLATION

 (cont

d)

IV. OPERATION

 (cont

d)

Summary of Contents for RET132EUT-FHS

Page 1: ...ed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure to help and assist you in every possible way OWNER S MANUAL OWNER S MANUAL OWNER S MANUAL OWNER S MANUAL OWNER S MANUAL Instructions for the installation operation and maintenance of all Traulsen INSTALLER COMPLETE THE FOLLOWING INFORMATI...

Page 2: ... heat I THE SERIAL TAG 1 FORT WORTH TX SERIAL MODEL VOLTS Hz PH TOTAL CURRENT AMPS MINIMUM CIRCUIT AMPS MAXIMUM OVERCURRENT PROTECTION AMPS LIGHTS WATTS HEATERS AMPS REFRIGERANT TYPE OZ DESIGN PRESSURE HIGH LOW REFRIGERANT TYPE OZ DESIGN PRESSURE HIGH LOW 370 60294 00 REV A READING THE SERIAL TAG Serial The permanent ID of your Traulsen Model The model of your Traulsen Volts Voltage Hz Cycle PH Ph...

Page 3: ...nal installa tion The bolts can then be removed with a 3 4 socket wrench Avoid laying the unit on its front side or back for removal of the pallet NOTE Traulsen does not recommend laying the unit down on its front side or back However if you must please be certain to allow the unit to remain in an up right position afterwards for 24 hours before plugging it in so that the compressor oils and refri...

Page 4: ...erator with two important additional features 1 the ability to introduce small amounts of heat into the cabinet and 2 increased air flow indicated by the presence of blowers mounted be hind the mullion The Even Thaw refrigerator operates continually the intro duction of frozen product lowers the cabinet temperature below the heater setpoint temperature 37 F This prompts the refrigeration system to...

Page 5: ... screws which hold it in place On solid door units the top hinge s contains a microswitch for controlling the interior lighting To reassemble the hinge reverse the previous procedure Fig 3 Fig 4 4 IV g ADJUSTING THE TEMPERATURE SCALE The Traulsen Even Thaw model is preset at the factory to operate within strict temperature parameters Should these settings require adjustment please contact our Serv...

Page 6: ... MAINTENANCE cont d V c REPLACING THE GASKETS To remove the gasket to be replaced grasp it firmly by one corner and pull it out Before attempting to install a new gasket both the unit and the gasket it self must be at room temperature Insert the four cor ners first by using a rubber mallet or hammer with a block of wood After the corners are properly inserted work your way towards the center from ...

Page 7: ... switch located behind the louvered panel Switching to the Refrigeration mode switch OFF will turn off two internal blower fans and will reduce the Thaw mode switch ON performance Subsequently switching to the Thaw mode will have reduced refrigeration performance The controller has been preset at the factory and should not require any adjustments Traulsen engineering EXPECTS no changes be made to ...

Page 8: ...r loading has been eliminated as a possible cause for extended thaw cycle times there are several system checks which can be done to diagnose the Traulsen Even Thaw unit First the amp draw should be checked early in the thaw cycle Shortly after loading the unit with frozen product the electronic control LED G should be illuminated as the cabinet temp will probably be in the 30 to 34 degree F range...

Page 9: ...EM HERE REMEDY 1 Condensing unit fails to start a Check if cord plug has been disconnected 2 Condensing unit operates for a Are doors closing properly prolonged periods or continuously b Dirty condenser or filter Clean properly c Evaporator coil iced Needs to defrost d Shortage of refrigerant call service 3 Food compartment is too warm a Check doors and gaskets for proper seal 4 Condensation on th...

Page 10: ...0308 00 All Models Sensor Probe 337 60309 00 RET132EUT RET232NUT Transformer 337 60309 01 RET232EUT Transformer 337 60311 00 RET132EUT RET232NUT Solid State Relay 337 60311 01 RET232EUT Solid State Relay 337 29447 00 All Models Defogger Switch 344 60126 00 All Models Thermometer 378 60013 00 All Models Call Service Light 346 28924 42 All Models Lock Keys T 42 346 13186 42 All Models Lock Cylinder ...

Page 11: ... 10 XI WIRING DIAGRAM ALL ONE SECTION MODELS ONLY ...

Page 12: ... 11 XII WIRING DIAGRAM MODELS RET232NUT FHS RET232NUT HHS ONLY ...

Page 13: ... 12 XIII WIRING DIAGRAM MODELS RET232EUT FHS RET232EUT HHS ONLY ...

Page 14: ...O THE EQUIPMENT OR ITS SALE OPERATION OR USE AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE OPERATION OR USE OTHER THAN AS STATED HEREIN INTERNATIONAL COMMERCIAL WARRANTY for Canadian warranties see domestic US warranty TRAULSEN CO INC warrants to the original purchaser the Refrigeration Equipment ma...

Page 15: ... 4 I Inside Door Pan 4 Interior Arrangements 3 J K L LED Lights 6 Legs 2 Loading Guidelines 6 Louver Assembly 4 M Mullion Air Ducts 6 N O Operational Troubleshooting 7 P Power Supply 3 Process Loading 4 Product Mix Issues 6 R Refrigerations System 3 Return Authorization 2 S Serial Tag 1 Spare Parts List 9 T Temperature Scale Adjustment 4 Troubleshooting 6 7 Tray Slides 3 7 U V Vinyl Protective Cov...

Page 16: ...Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2005 Traulsen All Rights Reserved ...

Reviews: