background image

-2-

II. RECEIPT INSPECTION

All Traulsen products are factory tested for perfor-
mance and are free from defects when shipped.  The
utmost care has been taken in crating this product to
protect against damage in transit.  All interior fittings
have been carefully secured and the legs or casters
are boxed and strapped inside to prevent damage.
Door keys will be attached to the handle with a nylon
strip.  The handle is protected by an easily removable
nylon netting.
You should carefully inspect your Traulsen unit for
damage during delivery.  If damage is detected, you
should save all the crating materials and make note
on the carrier

s Bill Of Lading describing this.  A freight

claim should be filed immediately.  If damage is sub-
sequently noted during or immediately after installa-
tion, contact the respective carrier and file a freight
claim.  Under no condition may a damaged unit be re-
turned to Traulsen without first obtaining written per-
mission (return authorization).

III. a - LOCATION:
Select a proper location for your Traulsen unit, away
from extreme heat or cold.  Allow enough clearance
between the unit and the side wall in order to make
use of the door stay open feature at 120

°

 (self-closing

feature operates up to 90

°

).  The door(s) must be able

to open a minimum of 90

°

 in order to make use of the

maximum clear door width available.
III. b - PACKAGING:
All Traulsen units are shipped from the factory bolted
to a sturdy wooden pallet and packaged in a durable
cardboard container.  The carton is attached to the
wooden skid with the use of large staples.  These
should first be removed to avoid scratching the unit
when lifting off the crate.
Most exterior stainless steel surfaces have a protec-
tive vinyl covering to prevent scratching during manu-
facturing, shipping and installation.  After the unit is
installed in place of service, remove and discard the
covering from all surfaces.
To remove the wooden pallet, first if at all possible, we
suggest that the cabinet remain bolted to the pallet
during all transportation to the point of final installa-
tion.  The bolts can then be removed with a 3/4

 socket

wrench.  Avoid laying the unit on its front, side or back
for removal of the pallet.
NOTE: Traulsen does not recommend laying the unit
down on its front, side or back.  However, if you must
please be certain to allow the unit to remain in an up-
right position afterwards for 24 hours before plugging
it in so that the compressor oils and refrigerant may
settle.
6

 high stainless steel legs are supplied standard for

all Traulsen reach-in Even-Thaw models.  Casters in

III. INSTALLATION

III. INSTALLATION

 (cont

d)

Fig. 1

Fig. 2

III. c - INSTALLING LEGS OR CASTERS:
lieu of legs are available as an optional accessory for
the same models.  These are shipped from the factory
packed inside a cardboard box which is strapped to
one of the shelves.  Remove the nylon strap and open
the box, it should contain either four (4) legs or four
(4) casters and sixteen (16) bolts.
WARNING: THE CABINET MUST BE BLOCKED AND
STABLE BEFORE INSTALLING LEGS OR CASTERS.
To install the legs or casters, first raise and block the
reach-in a minimum of 7

 from the floor.   For install-

ing legs, thread the legs into the threaded holes on
the bottom of the cabinet (see figure 1).  Be certain
that all legs are tightly secured (legs and casters
should be tightened to 300 inch/pounds, max).   When
the unit is set in its final position, it is important for
proper operation that the unit be level.  The legs are
adjustable for this purpose, turn the bottom of the leg
counter-clockwise to raise it, clockwise to lower it.
Level the unit from front to back as well as side to side
in this manner, using a level placed in the bottom of
the cabinet.

Please note that Traulsen units are not designed to be
moved while on legs.  If the unit requires moving, a
pallet jack or forklift should be used to prevent dam-
age.   For installing casters, the casters are 

plate

type, and require the use of four (4) bolts each to se-
cure them firmly to the cabinet bottom at each corner
(see figure 2).   The caster bolts are tightened using a
1/2

 socket wrench.

III. d - TRAY SLIDES:
Reach-In models are supplied with fourteen (14) pairs
of #1 type tray slides on 4

 centers.  These are shipped

installed from the factory, and are easily removable
for cleaning without tools.

Summary of Contents for RET132EUT-FHS

Page 1: ...ed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure to help and assist you in every possible way OWNER S MANUAL OWNER S MANUAL OWNER S MANUAL OWNER S MANUAL OWNER S MANUAL Instructions for the installation operation and maintenance of all Traulsen INSTALLER COMPLETE THE FOLLOWING INFORMATI...

Page 2: ... heat I THE SERIAL TAG 1 FORT WORTH TX SERIAL MODEL VOLTS Hz PH TOTAL CURRENT AMPS MINIMUM CIRCUIT AMPS MAXIMUM OVERCURRENT PROTECTION AMPS LIGHTS WATTS HEATERS AMPS REFRIGERANT TYPE OZ DESIGN PRESSURE HIGH LOW REFRIGERANT TYPE OZ DESIGN PRESSURE HIGH LOW 370 60294 00 REV A READING THE SERIAL TAG Serial The permanent ID of your Traulsen Model The model of your Traulsen Volts Voltage Hz Cycle PH Ph...

Page 3: ...nal installa tion The bolts can then be removed with a 3 4 socket wrench Avoid laying the unit on its front side or back for removal of the pallet NOTE Traulsen does not recommend laying the unit down on its front side or back However if you must please be certain to allow the unit to remain in an up right position afterwards for 24 hours before plugging it in so that the compressor oils and refri...

Page 4: ...erator with two important additional features 1 the ability to introduce small amounts of heat into the cabinet and 2 increased air flow indicated by the presence of blowers mounted be hind the mullion The Even Thaw refrigerator operates continually the intro duction of frozen product lowers the cabinet temperature below the heater setpoint temperature 37 F This prompts the refrigeration system to...

Page 5: ... screws which hold it in place On solid door units the top hinge s contains a microswitch for controlling the interior lighting To reassemble the hinge reverse the previous procedure Fig 3 Fig 4 4 IV g ADJUSTING THE TEMPERATURE SCALE The Traulsen Even Thaw model is preset at the factory to operate within strict temperature parameters Should these settings require adjustment please contact our Serv...

Page 6: ... MAINTENANCE cont d V c REPLACING THE GASKETS To remove the gasket to be replaced grasp it firmly by one corner and pull it out Before attempting to install a new gasket both the unit and the gasket it self must be at room temperature Insert the four cor ners first by using a rubber mallet or hammer with a block of wood After the corners are properly inserted work your way towards the center from ...

Page 7: ... switch located behind the louvered panel Switching to the Refrigeration mode switch OFF will turn off two internal blower fans and will reduce the Thaw mode switch ON performance Subsequently switching to the Thaw mode will have reduced refrigeration performance The controller has been preset at the factory and should not require any adjustments Traulsen engineering EXPECTS no changes be made to ...

Page 8: ...r loading has been eliminated as a possible cause for extended thaw cycle times there are several system checks which can be done to diagnose the Traulsen Even Thaw unit First the amp draw should be checked early in the thaw cycle Shortly after loading the unit with frozen product the electronic control LED G should be illuminated as the cabinet temp will probably be in the 30 to 34 degree F range...

Page 9: ...EM HERE REMEDY 1 Condensing unit fails to start a Check if cord plug has been disconnected 2 Condensing unit operates for a Are doors closing properly prolonged periods or continuously b Dirty condenser or filter Clean properly c Evaporator coil iced Needs to defrost d Shortage of refrigerant call service 3 Food compartment is too warm a Check doors and gaskets for proper seal 4 Condensation on th...

Page 10: ...0308 00 All Models Sensor Probe 337 60309 00 RET132EUT RET232NUT Transformer 337 60309 01 RET232EUT Transformer 337 60311 00 RET132EUT RET232NUT Solid State Relay 337 60311 01 RET232EUT Solid State Relay 337 29447 00 All Models Defogger Switch 344 60126 00 All Models Thermometer 378 60013 00 All Models Call Service Light 346 28924 42 All Models Lock Keys T 42 346 13186 42 All Models Lock Cylinder ...

Page 11: ... 10 XI WIRING DIAGRAM ALL ONE SECTION MODELS ONLY ...

Page 12: ... 11 XII WIRING DIAGRAM MODELS RET232NUT FHS RET232NUT HHS ONLY ...

Page 13: ... 12 XIII WIRING DIAGRAM MODELS RET232EUT FHS RET232EUT HHS ONLY ...

Page 14: ...O THE EQUIPMENT OR ITS SALE OPERATION OR USE AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE OPERATION OR USE OTHER THAN AS STATED HEREIN INTERNATIONAL COMMERCIAL WARRANTY for Canadian warranties see domestic US warranty TRAULSEN CO INC warrants to the original purchaser the Refrigeration Equipment ma...

Page 15: ... 4 I Inside Door Pan 4 Interior Arrangements 3 J K L LED Lights 6 Legs 2 Loading Guidelines 6 Louver Assembly 4 M Mullion Air Ducts 6 N O Operational Troubleshooting 7 P Power Supply 3 Process Loading 4 Product Mix Issues 6 R Refrigerations System 3 Return Authorization 2 S Serial Tag 1 Spare Parts List 9 T Temperature Scale Adjustment 4 Troubleshooting 6 7 Tray Slides 3 7 U V Vinyl Protective Cov...

Page 16: ...Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2005 Traulsen All Rights Reserved ...

Reviews: