VIEWING SENSOR TEMPERATURES:

These parameters allow a service technician or customer to view the temperature of all sensors within 

the unit.  The temperatures cannot be adjusted.

Follow the instructions to enter the customer access code on page 10.  When the control displays      

Thermostat Set Point                , press the DOWN arrow key            unit the display reads               

               Cabinet Air Sensor, Evaporator Coil Sensor,                and Disharge Line Sensor                or 

press the SET button          .  The display will read Thermostat Set Point               .  

Press the UP or DOWN arrow keys                    to scroll through the parameters or press the ALARM 

CANCEL button            to exit.

VII. r - DOOR OPEN ICON:

The door open icon is located on the control face, directly below the Alarm Cancel button (On/Off button 

for heated cabinet models).  This feature illuminates on all solid and hinged glass door models

1

 whenever 

one or more of the doors is opened, and stops illuminating upon all doors being closed.  There are no 

operator adjustable parameters for this feature.

1= This feature is not included on either fire-rated or sliding glass door models.

VII. s - HOT FOOD UNITS, ADJUSTING THE THERMOSTAT & TURNING THE UNIT OFF/ON:

This parameter sets the desired cabinet temperature.   Please note that hot food units are delivered 
from the factory set to the OFF position.

Follow the instructions to enter the customer access code on page 10.  When the control reads                      

 

    Thermostat Set Point, press the set button          .   

Use the arrow keys                    to adjust the temperature to your desired setting.  When the display 

shows the temperature you want press the set button          .  The display will then read 

               Thermostat Set Point.  You can use the up or down                  arrow keys to scroll to the 
next parameter or press the alarm cancel button          to exit.

VII. INTELA-TRAUL

®

 (continued)

-18-

)

)

)

SET     

SET

SET

Summary of Contents for R & ASeries

Page 1: ...day It is our pleasure to help and assist you in every possible way OWNER S MANUAL Instructions for the installation operation and maintenance of all Traulsen R A Series Reach In Roll In Refrigerators...

Page 2: ...e Alarm Style Page 17 q Viewing Sensor Temperatures Page 18 r Door Open Icon Page 18 s Hot Food Units Adjusting The Thermostat Page 18 t Hot Food Units Turning The Unit OFF ON Page 19 u Hot Food Units...

Page 3: ...t on its front side or back for removal of the pallet NOTE DO NOT LAY THE UNIT ON ITS SIDE DURING TRANSPORTATION OR INSTALLATION Roll Thru models also include special interior wood bracing intended to...

Page 4: ...e bottom door opening Next loosen the thumb screws located along the floor at the threshold Place the ramp s on top of the loosened thumb screws and secure tabs on each end to breaker strips with thum...

Page 5: ...III INSTALLATION continued III h REMOTE INSTALLATION cont d Refrigerant line installation must be done in accordance with good practice and local regulations See section III g for information concerni...

Page 6: ...an delay controls function upon termination of a defrost cycle is two fold First to prevent blowing warm air into the food storage area Second to prevent any condensation on the defrost coil from bein...

Page 7: ...rted work your way towards the center from both ends by gently hitting with a mallet until the gasket is completely seated in place see figure 11 for proper gasket placement NOTE The gasket may appear...

Page 8: ...rvice agents is posted on our company s official website www traulsen com under the SERVICE PARTS button VI c WARRANTY REGISTRATION For your convenience the warranties on your new Traulsen unit may be...

Page 9: ...eded for the prevailing ambient conditions from 0 100 of the time each day It is used to prevent condensation from forming around the perimeter of the doors 6 Alarms See the following pages for explan...

Page 10: ...the door or press the alarm cancel button If the door remains open for an additional 5 minutes the audible alarm will sound again n a on fire rated and sliding glass door models CONDENSER CLEAN The a...

Page 11: ...l read Customer Service Access Press the set button The display will show three zeros with the left zero flashing Press the set button The display will show three zeros with the center zero flashing P...

Page 12: ...your desired setting When the display shows the temperature you want press the set button The display will then read Thermostat Set Point You can use the up or down arrow keys to scroll to the next pa...

Page 13: ...display shows the temperature you want press the set button The display will then read Thermostat Set Point You can use the up or down arrow keys to scroll to the next parameter or press the alarm ca...

Page 14: ...5 5 00 a m H11 11 00 a m H17 5 00 p m H23 11 00 p m H06 6 00 a m H12 12 00 p m H18 6 00 p m H24 12 00 a m Follow the instructions to enter the customer access code on page 10 When the control displays...

Page 15: ...ct day is displayed press the set button The display will then read Thermostat Set Point You can use the up or down arrow keys to scroll to the next parameter press the alarm cancel button to exit VII...

Page 16: ...ton The display will show OFF Press either arrow key ON The display will show Press the set button The display will then read and start the defrost cycle immediately The defrost icon will be lit and t...

Page 17: ...00 a m 120 12 00 p m 180 6 00 p m 240 12 00 a m 063 6 30 a m 123 12 30 p m 183 6 30 p m 243 12 30 a m 070 7 00 a m 130 1 00 p m 190 7 00 p m 010 1 00 a m 073 7 30 a m 133 1 30 p m 193 7 30 p m 013 1...

Page 18: ...w keys to scroll to the next parameter or press the alarm cancel button to exit VII p SETTING THE AUDIBLE ALARM STYLE This parameter will allow the customer to turn on off the audible alarm feature on...

Page 19: ...n all solid and hinged glass door models1 whenever one or more of the doors is opened and stops illuminating upon all doors being closed There are no operator adjustable parameters for this feature 1...

Page 20: ...n in memory VII v HOT FOOD UNITS TEMPERATURE ADJUSTMENT Press the SET button and the UP ARROW button at the same time The display will flash the current temperature setting or OFF if the unit is turne...

Page 21: ...INTELA TRAUL setting too high readjust per instructions on page 11 4 Food compartment is too cold a Perhaps a large quantity of very cold or frozen food has recently been added Allow adequate time for...

Page 22: ...ent hinge cover Hinge Spring Assist SER 29021 03 Alternative hinge spring assist Hinge Assembly W Stop Feature SER 40677 02 Alternative hinge stop feature Hinge Assembly SER 28583 00 Replacement hinge...

Page 23: ...of a Traulsen refrigeration product resulting in corrosion Avoid use of these on or around a Traulsen refrigeration product if at all possible XII STAINLESS STEEL OVERVIEW XII c UNDERSTANDING THE CAUS...

Page 24: ...hen it first becomes visible When rust occurs do not allow it to remain for any period of time and remove it using the following method STEP ONE Use a lightly abrasive compound free of harmful chlorid...

Page 25: ...purchaser the Refrigeration Equipment shall be manufactured free from defects in material and workmanship under normal use and service for a period of one 1 year from date of shipment Under this warr...

Page 26: ...lue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2015 Traulsen All R...