VI. a - SERVICE INFORMATION:

Before calling for service, please check the following:

 

Is the electrical cord plugged in?

 

Is the fuse OK or circuit breaker on?

 

Is the power switch 

ON

If  after  checking  the  above  items  and  the  unit  is  still 

not operating properly, please contact an authorized 

Traulsen service agent.  A complete list of authorized 

service agents was provided along with your Traulsen 

unit.  If you cannot locate this, you may also obtain the 

name of a service agent from the SERVICE & PARTS 

button from our website: www.traulsen.com.

If service is not satisfactory, please contact our in-house 

service department at:

  Traulsen

 

 

4401 Blue Mound Road

 

 

Fort Worth, TX 76106

 

 

(800) 825-8220

Traulsen reserves the right to change specifications or 

discontinue models without notice.

VI. b - SPARE PARTS:

Spare or replacement parts may be obtained through a 

parts supplier or one of our authorized service agents.  

A complete list of authorized service agents is posted 

on our company

s official website www.traulsen.com, 

under the  SERVICE & PARTS button. 

VI. c - WARRANTY REGISTRATION:

For  your  convenience,  the  warranties  on  your  new 

Traulsen unit may be registered with us on-line at www.

traulsen.com, under the  SERVICE & PARTS button. 

     

V. g - REPLACING THE LIGHT BULB:

All Traulsen R & A Series models are supplied with 

incandecent lighting unless optional fluorescent 

lighting  was  ordered  (except  for  sliding  glass  door 

models for which fluorescent lights are supplied 

standard).

The bulb is a 115 volt/40 watt, T-6

1

intermediate clear 

refrigerator lamp.  It is mounted at the top front of the 

cabinet at the center, and is located behind a plastic light 

cover on refrigerator and freezer model. 
Heated  units  (RHF/AHF/RIH/AIH/RDH/ADH/RIDH/AIDH) 

are equipped with a similar type bulb, however this is 

shatterproof because these models do not include a 

plastic light cover.  
To replace the bulb, first remove the light cover (if so 

equipped).  This can be accomplished by squeezing it 

together on both sides until it comes free.  Replace the 

light bulb, then squeeze both sides of the light cover 

together and replace in its original position.

   

Summary of Contents for R & ASeries

Page 1: ...day It is our pleasure to help and assist you in every possible way OWNER S MANUAL Instructions for the installation operation and maintenance of all Traulsen R A Series Reach In Roll In Refrigerators...

Page 2: ...e Alarm Style Page 17 q Viewing Sensor Temperatures Page 18 r Door Open Icon Page 18 s Hot Food Units Adjusting The Thermostat Page 18 t Hot Food Units Turning The Unit OFF ON Page 19 u Hot Food Units...

Page 3: ...t on its front side or back for removal of the pallet NOTE DO NOT LAY THE UNIT ON ITS SIDE DURING TRANSPORTATION OR INSTALLATION Roll Thru models also include special interior wood bracing intended to...

Page 4: ...e bottom door opening Next loosen the thumb screws located along the floor at the threshold Place the ramp s on top of the loosened thumb screws and secure tabs on each end to breaker strips with thum...

Page 5: ...III INSTALLATION continued III h REMOTE INSTALLATION cont d Refrigerant line installation must be done in accordance with good practice and local regulations See section III g for information concerni...

Page 6: ...an delay controls function upon termination of a defrost cycle is two fold First to prevent blowing warm air into the food storage area Second to prevent any condensation on the defrost coil from bein...

Page 7: ...rted work your way towards the center from both ends by gently hitting with a mallet until the gasket is completely seated in place see figure 11 for proper gasket placement NOTE The gasket may appear...

Page 8: ...rvice agents is posted on our company s official website www traulsen com under the SERVICE PARTS button VI c WARRANTY REGISTRATION For your convenience the warranties on your new Traulsen unit may be...

Page 9: ...eded for the prevailing ambient conditions from 0 100 of the time each day It is used to prevent condensation from forming around the perimeter of the doors 6 Alarms See the following pages for explan...

Page 10: ...the door or press the alarm cancel button If the door remains open for an additional 5 minutes the audible alarm will sound again n a on fire rated and sliding glass door models CONDENSER CLEAN The a...

Page 11: ...l read Customer Service Access Press the set button The display will show three zeros with the left zero flashing Press the set button The display will show three zeros with the center zero flashing P...

Page 12: ...your desired setting When the display shows the temperature you want press the set button The display will then read Thermostat Set Point You can use the up or down arrow keys to scroll to the next pa...

Page 13: ...display shows the temperature you want press the set button The display will then read Thermostat Set Point You can use the up or down arrow keys to scroll to the next parameter or press the alarm ca...

Page 14: ...5 5 00 a m H11 11 00 a m H17 5 00 p m H23 11 00 p m H06 6 00 a m H12 12 00 p m H18 6 00 p m H24 12 00 a m Follow the instructions to enter the customer access code on page 10 When the control displays...

Page 15: ...ct day is displayed press the set button The display will then read Thermostat Set Point You can use the up or down arrow keys to scroll to the next parameter press the alarm cancel button to exit VII...

Page 16: ...ton The display will show OFF Press either arrow key ON The display will show Press the set button The display will then read and start the defrost cycle immediately The defrost icon will be lit and t...

Page 17: ...00 a m 120 12 00 p m 180 6 00 p m 240 12 00 a m 063 6 30 a m 123 12 30 p m 183 6 30 p m 243 12 30 a m 070 7 00 a m 130 1 00 p m 190 7 00 p m 010 1 00 a m 073 7 30 a m 133 1 30 p m 193 7 30 p m 013 1...

Page 18: ...w keys to scroll to the next parameter or press the alarm cancel button to exit VII p SETTING THE AUDIBLE ALARM STYLE This parameter will allow the customer to turn on off the audible alarm feature on...

Page 19: ...n all solid and hinged glass door models1 whenever one or more of the doors is opened and stops illuminating upon all doors being closed There are no operator adjustable parameters for this feature 1...

Page 20: ...n in memory VII v HOT FOOD UNITS TEMPERATURE ADJUSTMENT Press the SET button and the UP ARROW button at the same time The display will flash the current temperature setting or OFF if the unit is turne...

Page 21: ...INTELA TRAUL setting too high readjust per instructions on page 11 4 Food compartment is too cold a Perhaps a large quantity of very cold or frozen food has recently been added Allow adequate time for...

Page 22: ...ent hinge cover Hinge Spring Assist SER 29021 03 Alternative hinge spring assist Hinge Assembly W Stop Feature SER 40677 02 Alternative hinge stop feature Hinge Assembly SER 28583 00 Replacement hinge...

Page 23: ...of a Traulsen refrigeration product resulting in corrosion Avoid use of these on or around a Traulsen refrigeration product if at all possible XII STAINLESS STEEL OVERVIEW XII c UNDERSTANDING THE CAUS...

Page 24: ...hen it first becomes visible When rust occurs do not allow it to remain for any period of time and remove it using the following method STEP ONE Use a lightly abrasive compound free of harmful chlorid...

Page 25: ...purchaser the Refrigeration Equipment shall be manufactured free from defects in material and workmanship under normal use and service for a period of one 1 year from date of shipment Under this warr...

Page 26: ...lue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration 2015 Traulsen All R...

Reviews: