Trapzilla TSS-27 Installation & Maintenance Instructions Manual Download Page 25

©2014 Thermaco, Inc. All rights reserved  •  Patented/Patents Pending  •  Specifications subject to change without notice

Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651

MNL-TSS 25

A THERMACO® Technology

Limited Warranty & Remedy

Thermaco, Inc. warrants to the original user that the products manufactured by it delivered with this warranty shall 

be free from material defects in workmanship and materials for a period of 12 months from the date of invoice to 

the distributor (if sold by an authorized Thermaco distributor) or the date of invoice to the purchaser (if sold directly 

by Thermaco, Inc.), but in no event longer than 15 months from date of shipment from Thermaco’s production 

facility.

Any claim must be made in writing to Thermaco at 646 Greensboro Street, Asheboro, NC  27203 promptly after 

discovery of the defect and within the applicable warranty period.  The product must be delivered, prepaid, to 

Thermaco, together with proof of purchase and a return authorization number issued by Thermaco. If Ther-

maco determines upon examination that the component is defective and that the warranty conditions are met, 

Thermaco’s sole obligation under this warranty, and the purchaser’s sole and exclusive remedy, is the repair or 

replacement, at Thermaco’s option, of the defective component, including parts and labor.  The replacement will 

be furnished F.O.B. point of shipment. If Thermaco determines that the component is not defective or that the 

other conditions of this warranty are not met, then any return of such part to the purchaser shall be at purchaser’s 

cost.

This warranty shall not cover any defect in otherwise covered products resulting directly or indirectly from: (i) 

failure to properly install, operate or maintain the product in accordance with Thermaco’s instructions and pro-

cedures, including, without limitation, use in excess of rated flow, use to remove emulsified fats and oils or use 

that fails to comply with applicable laws, regulations or codes; (ii) damage in transit, handling or installation; (iii) 

modifications, adjustments, repairs, or alterations made by unauthorized persons; or (iv) other causes not arising 

out of defects in workmanship or materials. Thermaco shall not be responsible for damage to products resulting 

from vault flooding, sewer line back-up, pumping or lift station failure, ambient water flow or other sources of water 

damage.  This warranty does not cover equipment or parts not manufactured by Thermaco.  Purchaser’s costs 

relating to any service, adjustment, removal, repair, packing, or otherwise incurred with respect to the defect prior 

to submission for warranty are the responsibility of purchaser.

No distributor, sales person or other person is authorized to make any warranty statements on behalf of Therma-

co regarding Thermaco products other than as set forth in this warranty.  This statement of warranty supersedes 

any quote, brochure, or other statement or document with respect to warranty of Thermaco products.   

EXCEPT AS EXPRESSLY SET FORTH ABOVE, THERMACO, INC. MAKES NO REPRESENTATIONS, WAR-

RANTIES OR GUARANTEES, EITHER EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, AS 

TO 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

, WHETHER OR NOT THERMACO 

HAD KNOWLEDGE OF PURCHASER’S PARTICULAR REQUIREMENTS OR NEEDS, OR WITH RESPECT TO 

ODOR GENERATION OR OTHER INCIDENTALS RELATING TO USE OF THE PRODUCT.

The sole and exclusive remedy with respect to this warranty any other claim relating to defects or any other con-

dition or use of Thermaco products, however caused, and whether such claim is based upon warranty, contract, 

tort, strict liability or any other theory, is LIMITED to the repair or replacement of the product, excluding labor or 

any other cost to remove or install said the product or, at Thermaco’s option, repayment of the purchase price.  IN 

NO EVENT SHALL THERMACO, INC. BE LIABLE, WHETHER IN CONTRACT, WARRANTY, TORT (INCLUD-

ING NEGLIGENCE), STRICT LIABILITY, INDEMNITY OR ANY OTHER LEGAL THEORY, FOR INCIDENTAL 

OR CONSEQUENTIAL DAMAGES, OR FOR ANY OTHER LOSS OR COST OF A SIMILAR TYPE.  UNDER 

NO CIRCUMSTANCES WILL THE AGGREGATE LIABILITY OF THERMACO FOR ANY CAUSE OF ACTION 

RELATED TO THE PRODUCTS COVERED HEREBY EXCEED THE NET PURCHASE PRICE RECEIVED BY 

THERMACO FOR THE PRODUCTS. Any action or suit by purchaser against Thermaco relating to Thermaco 

products must be brought within one (1) year of the date of the invoices referenced above. The exclusions and 

limitations set forth herein are separate and independent from any remedies which purchaser may have here-

under and shall be given full force and effect whether or not any or all such remedies shall be deemed to have 

failed of their essential purpose.

Summary of Contents for TSS-27

Page 1: ...Inc P O Box 2548 Asheboro NC 27204 Toll Free 800 633 4204 V 336 629 4651 F 336 626 5739 E mail info thermaco com www trapzilla com Installation Maintenance Instructions For Trapzilla Solids Separators...

Page 2: ...Technology Section I Trapzilla Solids Separators 3 System Overview 3 Section II Models and Options 4 In Ground Models 4 Above Ground Models 5 Basic Models 6 Options 7 Section III TSS Installation 8 Pl...

Page 3: ...lity Trapzilla Solids Interceptor units are designed to treat high flows of kitchen drainwater with large solids storage capacity within a small footprint unit These units are easy to manueuver into p...

Page 4: ...6 626 5739 Decimals XX 03 XXX 015 Unless otherwise specified Dimensions are in inches Tolerances Angular 1 CHECKED SIZE REV NO DWG NO PART NO C SCALE RELEASE DATE SHEET OF ENGINEERING DRAWN DATE THIRD...

Page 5: ...retention capacity capable of handling flow rates of up to 150 gpm Equipped with 4 inlet outlet 2 vessel vent connection and 4 Low Head Flow Control Accessory to limit flow to 75 gpm Comes with Standa...

Page 6: ...nd 4 Low Head Flow Control Accessory to limit flow to 75 gpm Comes with Standard Adapter Top Cover with 22 diameter lid 70 gallons of solids retention capacity capable of handling flow rates of up to...

Page 7: ...ion in high foot traffic areas and 4 Brass cleanout port FTCA 22 not shown 22 diameter cover available for In Ground installations 1 1 2 2 3 3 4 4 A A B B C C D D THIS DRAWING CONTAINS PROPRIETARY AND...

Page 8: ...tions Do not reduce the pipe sizing on the outlet piping Do not install P trap on outlet connection of system Note The system already has a in ternal gas trap Flow Controls Trapzilla systems are suppl...

Page 9: ...d connect 2 vent lines as indicated below Plumbing Installation 1 1 2 2 3 3 4 4 A B C D THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITH...

Page 10: ...fied Dimensions are in inches Tolerances Angular 1 CHECKED SIZE REV NO DWG NO PART NO C SCALE RELEASE DATE SHEET OF ENGINEERING DRAWN DATE THIRD Plumbing Installation for one Solids Separator Each Tra...

Page 11: ...Use a 4 100 mm Two Way Cleanout for TSS 70 TSS 95 TZ 400 and TZ 600 Unit Installations 1 1 2 2 3 3 4 4 A B C D THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL THIS DRAWING MAY NOT BE REPRODUC...

Page 12: ...herwise specified Dimensions are in inches Tolerances Angular 1 CHECKED SIZE REV NO DWG NO PART NO C SCALE RELEASE DATE SHEET OF ENGINEERING DRAWN DATE THIRD ANGLE Use a 4 100 mm Two Way Cleanout for...

Page 13: ...THIRD ANGLE PROJECTION Outlet Outlet Cleanout Cleanout Cleanout Cleanout Cleanout Cleanout Inlet Trapzilla TSS 95 unit Trapzilla TZ 600 unit Trapzilla TZ 600 unit Outlet Vent Connect to facility vent...

Page 14: ...TE THIRD ANGLE PROJECTION Use a 4 100 mm Two Way Cleanout for TSS 70 TSS 95 TZ 400 and TZ 600 Unit Installations Cleanout Cleanout Cleanout Cleanout Cleanout Cleanout Cleanout Outlet Outlet Inlet Trap...

Page 15: ...h all SSA models SSOP 70 95 Support Stand TSS 95 Trapzilla Base Model 2 2 3 3 4 4 A B C D THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WI...

Page 16: ...T WITHOUT WRITTEN CONSENT FROM THERMACO INC POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEE...

Page 17: ...lla inlet with the drainage piping The ECA TSS 29 may be trimmed in the field to fit Trim both the inner and outer portions of the extension collar to make shorter than collapsed height Thermaco Inc a...

Page 18: ...tion In Ground Installation When installing multiple Trapzilla units in series the change in elevation from the inlet to the outlet of a unit requires each preceeding unit to be installed 1 higher tha...

Page 19: ...ion collar adapter ring from the unit with the extension collar still in place On the underside of the cover mark the excess extension col lar length at the bottom of the four 4 skirt portions of the...

Page 20: ...e adapter ring and the small cover with the brass nuts and flat washers provid ed Seal the gap between the 18 extension collar and extension collar adapter ring using a silicone sealant Step 3 Remove...

Page 21: ...nuously and completely surrounding the Trapzilla Solids Separator and Extension Collars if applicable to ensure proper strength and security Buoyancy Calculations TSS Models Components Amount of Concr...

Page 22: ...ng weight loads preparation of the floor for installation and any construction necessary for installation of the suspension kit Using the HA 70 95 model a Trapzilla unit may be suspended from a ceilin...

Page 23: ...eparator follow the instructions below 1 Remove four nuts washers securing the Solid Top Cover Note the size of the unit which is marked on the cover by a metal plate 2 Place a grease sludge dipstick...

Page 24: ...solids from the top of the tank Be sure to lower the hose all the way to the bottom of the Trapzilla unit so that solids may be entirely removed The Grease or Solids building up inside the Trapzilla...

Page 25: ...ucts resulting from vault flooding sewer line back up pumping or lift station failure ambient water flow or other sources of water damage This warranty does not cover equipment or parts not manufactur...

Reviews: