Page 8
47-01
Hunt Group Access Code
_____ 1
Form 48-01-xx - Hunt Group Members
Form 48-01 determines the extensions that are members of Hunt
Group 1 during day service. Program this form with the extension
numbers that are connected to the voice mail system.
48-01-xx
Hunt Group Members
____ ____
____ ____
So Form 46-01-xx through 46-40-xx may exist in your SK-200.
Form 47-01 – Hunt Group Access Code
In order for stations to easily call the voice mail system, each of the
voice mail extensions must be assigned to a Hunt Group. We
recommend that you program your voice mail ports into Hunt Group 1.
Form 47-01 assigns the Access Code and the Hunt type to the First
Hunt Group.
The Access code you apply for this group is entirely up to you, but the
guidelines for Hunt Group assignment are as follows:
1
The Access code for the Hunt Group must be the same
length as your extension numbering plan.
The Access code must be unique to the system. Your
access code cannot be the same as an extension in the
system.
2
Your access code can begin with the digits 1 through 6.
2 digit extensions: 10 through 69 are OK.
3 digit extensions: 100 through 699 are OK
4 digit extensions: 1000 through 6999 are OK
Note: The access code you select for the Hunt Group cannot
conflict with an existing extension in the SK-824.
Page 9
TMS Information
The following parameters have been pre-set by TransTel to enable
Plug-N-Play operation.
Database Entry/Verification TMS-100
System Setup
Option 1. System Dial Codes
Item
Entry
# Dial code to put a caller on transfer hold
F,
# Dial code to use when there is no transfer dialtone
(blank)
# Dial code to return to caller after Ring No Answer
(blank)
# Dial code to return to caller when there is a Busy
F-
# Dial code to use after a call screening reject
F
# Dial code to connect the caller to the extension
H
# Number of seconds to wait for dialtone detection
0
# Number of 1/100 seconds to use for Flash time
35
# Which DTMF tone to listen to for answer detection
A
# Which DTMF tone to listen to for hangup detection
C
# What to dial BEFORE dialing the User ID extension
(blank)
# What to dial AFTER dialing the User ID extension
H
# What to dial when the system first starts up
(blank)
# What to dial when the system performs a shutdown
(blank)
# What to dial when a port goes off-hook
(blank)
Option 3. System Integration Patterns
If you use 2 digit extension numbering in your SK-200 the proper
Integration is already installed from the factory as listed below:
Item
Entry
Integration Timeout by 1/10
10
Forward from Ring No Answer
1300rr00xx
Forward from Ring No Answer
1100rr00xx
Forward from Ring No Answer
2500rr00xx
Forward from Ring No Answer
2100rr00xx
Forward from Ring No Answer
2300rr00xx
Forward from Busy extension
1200rr00xx
Forward from Busy extension
2200rr00xx
Direct call from extension
1400ee00xx
Direct call from a CO trunk
2ttttt00xx
Direct call record
1500ii00xx