What are systolic pressure and diastolic 

pressure? 

press

artery

vein

blood discharging

Systolic

relax

blood entering

Diastolic  

Irregular Heartbeat Detector

CAUTION

Why does my blood 

pressure fluctuate 

throughout the day?

Is the result the same if 

measuring on the right 

arm?

Why do I get a different 

blood pressure at home 

compared to the 

hospital?

1. Individual blood pressure 

varies multiple times everyday. It 

is also affected by the way you tie 

your cuff and your measurement 

position, so please take the 

measurement under the same 

conditions.

2.If the person takes medicine, 

the pressure will vary more.

3.Wait at least 3 minutes for 

another measurement.

The blood pressure is 

different even throughout the 

day due to weather, emotion, 

exercise etc, Also, there is the 

“white coat” effect, which means 

blood pressure usually 

increases in clinical settings.

It is ok for both arms, but 

there will be some different 

results for different people. We 

suggest you measure the same 

arm every time.

What you need to pay 

attention to when you 

measure your blood 

pressure at home: 

If the cuff is tied properly. 

If the cuff is too tight or too 

loose.

If the cuff is tied on the upper 

arm.

If you feel anxious.

Taking 2-3 deep breaths 

before beginning will be better for 

measuring.        

Advice: Relax yourself for 4-5 

minutes until you calm down.

When ventricles contract and pump blood 

out of the heart, the blood pressure 

reaches its maximum value in the cycle, 

which is called systolic pressure. When 

the ventricles relax, the blood pressure 

reaches its minimum value in the cycle, 

which is called diastolic pressure.

The appearance of the IHB icon indicates that a pulse irregularity consistent 

with an irregular heartbeat was detected during measurement. Usually this is 

NOT a cause for concern. However, if the symbol appears often, we 

recommend you seek medical advice. Please note that the device does not 

replace a cardiac examination, but serves to detect pulse irregularities at an 

early stage.

An irregular heartbeat is detected when a heartbeat rhythm varies while the unit is measuring

the systolic and diastolic blood pressure.During each measurement, the monitor records all the

pulse intervals and calculate the average ; if there are two or more pulse intervals ,the difference

between each interval and the average is more than the average value of ±25% , or there are four

or more pulse intervals ,the difference between each interval and the average is more than the

average value of ±15%,the irregular heartbeat symbol appears on the display when the

measurement results are appear.

What is the standard blood pressure classification?

The chart on the right is the 

standard blood pressure classifi-

cation published by American

Heart Association (AHA).

Please consult a physician if your measuring result falls outside the range. 

Please note that only a physician can tell whether your blood pressure value 

has reached a dangerous point.

CAUTION

Blood Pressure Category

Normal

Elevated

High Blood Pressure

(Hypertension) Stage 1

High Blood Pressure

(Hypertension) Stage 2

Hypertensive Crisis

(Consult your doctor immediately)

Systolic

mmHg (upper#)

Diastolic

mmHg (lower#)

less than 120

120-129

130-139

140 or higher

Higher than 180

and

or

or

and/or

less than 80

80-89

90 or higher

Higher than 120

This chart reflects blood pressure categories defined by American Heart Association.

and

less than 80

ABOUT BLOOD PRESSURE

ABOUT BLOOD PRESSURE

17

16

Summary of Contents for TMB-1591-BS

Page 1: ...ghly Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB 1591 BS Please keep this manual well in order to reference in future Arm Type version 1 0 Guangdong Transtek Medical Electron...

Page 2: ...MATION FOR USER 14 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 16 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irregular heartbeat de...

Page 3: ...l booklet To signify that the instruction manual booklet must be read Symbol for Manufacturer Symbol for Serial Number Symbol for Type BF applied part Symbol for Direct Current The symbol indicates th...

Page 4: ...h frequency HF surgical equipment at the same time CAUTION Warning This device is not AP APG equipment Do not use the device where flammable anesthetic are present or in environments mixture with air...

Page 5: ...nt The grade of the blood pressure Component list of pressure measuring system 1 Cuff 2 Air pipe 3 PCBA 4 Pump 5 Valve Monitor Components BATTERY COMPARTMENT ON STANDBY BUTTON LCD DISPLAY AIR HOSE AIR...

Page 6: ...e old batteries are harmful to the environment do not dispose with other daily trash Remove the old batteries from the device and follow your local recycling guidelines CAUTION Replace the batteries w...

Page 7: ...cuff should be snug but not too tight You should be able to insert one finger between the cuff and your arm 3 Sit comfortably with your arm resting on a flat surface 2 3cm 4 Correct position Bare you...

Page 8: ...by button another reading is initiated If the user presses and holds the On Standby button for 2 seconds the device powers down Or if there is no operation after a 10 seconds of inactivity the device...

Page 9: ...urine Measurements may be inaccurate if taken in the following circumstances Maintenance In order to get the best performance please follow the instructions below Put in a dry place and avoid the suns...

Page 10: ...the IHB icon indicates that a pulse irregularity consistent with an irregular heartbeat was detected during measurement Usually this is NOT a cause for concern However if the symbol appears often we r...

Page 11: ...DIA 40mmHg 130mmHg 5 3kPa 17 3kPa Pulse value 40 199 beat minute Pressure 5 40 within 3mmHg pulse value 5 Temperature 20 C to 60 C A relative humidity range of 93 non condensing at a water vapour pre...

Page 12: ...with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation...

Page 13: ...ecessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the excepted service life 2 Guidance and manufacturer s declaration electro...

Page 14: ...IMMUNITY to RF wireless communicati ons equipment Band MHz Distance m IEC 60601 1 2 Test Level V m TETRA 400 Pulse modulation 18 Hz GMRS 460 FRS 460 FM 5k Hz deviation 1 kHz sine LTE Band 13 17 Pulse...