LCD display

Tips:

Inflating and measuring.

Start the Measurement

2.

In this manual, the measurement of User 1 as an example.

Press the User 1 button to turn on the monitor and it will finish the 

whole measurement, and then save the measure data for User 1. The 

same to the User 2.

Adjust the zero . If the 

measure data don’t upload to 

the bridge in time, the icon      

will display.

Press the User 1 to power off , otherwise it 

will turn off within one minute.

Display and save the results will 

transmit to the bridge through the 

wireless.

Press the Guest button to turn on the monitor and it will finish the whole 

measurement for Guest, but not save the measurement data.

A.when finish the whole measurement, press another button ,the blood 

monitor will begin measure again.

B.If the blood monitor not connect with  bridge, the icon of       will display. 

Maximum 60 records are both for User 1 and User 2.

1.

When the monitor is off, 

press the User 1 button to turn on the monitor. 

3

Please proceed to activate/synchronize before initial use of this equipment or when 

the measurement unit is changed. When the equipment is OFF, press and hold 

“GUEST” button to enter Activation / Synchronization Interface. After successful 

activation/synchronization, the equipment will display and transmit the measuring 

results after each measurement.

Activation 

/synchroniz

ation is 

proceeding

The 

measureme

-nt data is 

uploading

The data 

has been 

uploaded 

successfully

CAUTION

Interference may occur in the vicinity of equipment marked with the following symbol

      . And LS802-E may interfering vicinity electrical equipment.
Sensitive people, including pregnant women and those who implanted medical elec-

tronic instruments, should avoid using the unit whenever possible.
Keep the monitor at least 20 centimeters away from the human body (especially the 

head) when the data transmission is proceeding after measurement.
To enable the data transmission function, this product should be interconnected with 

Bridge in RF 915 MHz network.

How to mitigate  possible interference?

1. The range between the device and the Bridge should be reasonably close, from 1 

meter to 10 meters. Please ensure no obstacles between the device and the Bridge

so as to obtain quality connection and to lower the RF output range.

2. To avoid interference, other electronic devices (particularly those with wireless 

transmission / Transmitter) should be kept at least 1 meter away from the monitor.

Wireless Transmission 

Module No.
Frequency Range

Output Power Range

Supply Voltage

AW4431_915

915 - 918.5 MHz

+1 dBm

3.3V

When there is 

no record

MEASUREMENT

MEASUREMENT

Summary of Contents for LS802-E

Page 1: ...u very much for selecting TRANSTEK Blood Pressure Monitor LS802 E please keep well this manual in order to reference in future Arm Type Version 1 0 FCC ID OU9LS802 E02 GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO LTD Zone A 5 F Investment Building No 12 Huizhan East Rd Torch Development District Zhongshan Guangdong 528437 China ...

Page 2: ...SER 10 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 12 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Why my blood pressure is varies even in one day Why the blood pressure I get from the hospital is different from home If the result is the same if measuring on the right arm TROUBLESHOOTING 14 SPECIFICATIONS 15 AUTHORIZED COMPONENTS 1...

Page 3: ...e START STOP button to stop inflation The equipment is not AP APG equipment and not suitable for use in the presence of a flammable anesthetic mixture with air of with oxygen or nitrous oxide The operator shall not touch output of batteries adapter and the patient simultaneously To avoid measurement errors please avoid the condition of strong electromagnetic field radiated interference signal or e...

Page 4: ...measurement for user 2 and then save the measure data Data storage To remind the users that the measurement data don t upload to bridge in time Wireless transmitter The blood monitor and Bridge in communication Network connection The bridge not connect the network Shocking remainding Shocking will result in inaccurate Low battery Batteries are low and need to be replaced Measurement Unit of the bl...

Page 5: ...ws your blood circulation to recover For a meaningful comparison try to measure under similar conditions For example take daily measurements at approximately the same time on the same arm or as directed by a physician Tie the Cuff 1 Tie the cuff on your upper arm the position the tube off center toward the inner side of arm in line with the little finger 2 The cuff should be sung but not too tight...

Page 6: ...ssful activation synchronization the equipment will display and transmit the measuring results after each measurement Activation synchroniz ation is proceeding The measureme nt data is uploading The data has been uploaded successfully CAUTION Interference may occur in the vicinity of equipment marked with the following symbol And LS802 E may interfering vicinity electrical equipment Sensitive peop...

Page 7: ... it with a dry cloth in case Avoid the dusty and unstable temperature environment Avoid washing the cuff 11 10 Tips for measurement In a very cold environment Immediate measurement after tea coffee smoking When talking or moving your fingers When you want to discharge urine It can cause incorrectness if the measurement are taken in the following circumstances Within 20 minutes after taking a bath ...

Page 8: ...LOOD PRESSURE If the result is the same if measuring on the right arm ABOUT BLOOD PRESSURE Irregular Heartbeat Detector This Blood Pressure Monitor is equipped with an intelligent function of Irregular Heartbeat IHB Detector During each measurement this equipment records the heartbeat intervals and works out the standard deviation If the calculated value is larger than or equal to 15 this equipmen...

Page 9: ...th new batteries Batteries are inserted incorrectly Display is dim or show Batteries are low E 1 shows RF communication failed Check the database is power on or not Or synchronize the data operation E 3 shows E10 or E11 shows E20 shows Exxx shows on the display A calibration error occurred Retake the measurement If the problem persists contact the retailer or our customer service department for fu...

Page 10: ...This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harm...

Page 11: ...cle processes ISO EN 14971 2012 Medical devices Application of risk management to medical devices ISO EN 15223 1 2012 Medical devices Symbols to be used with medical device labels labelling and information to be supplied General requirements EN 1041 2008 Medical equipment manufacturers to provide information IEC 60601 1 2005 A1 2012 Medical electrical equipment Part 1 General requirements for basi...

Reviews: