INTRODUCTION

INTRODUCTION

General Description

Indications for Use

Measurement Principle

Consult a medical professional before using this device if you have an implanted cardiac 

device, such as a pacemaker or defibrillator.

Consult a medical professional before using this device during pregnancy.

1.

2.

Contraindications

Thank you for choosing this arm type Pro Cellular Blood Pressure Monitor (CH-B2-11-AA).  It is 

equipped with the following key features. Please read this manual to know how to use your 

Blood Pressure Monitor safely and correctly. Keep the manual well for future reference.

Safety Information

The symbols below might be in the user manual, labeling or other component. 

They are the requirement of standard and using. 

This product uses the Oscillometric Measuring method to detect blood pressure. Before every 

measurement, the unit establishes a “zero pressure” equivalent to the atmospheric pressure. 

Then it starts inflating the arm cuff, meanwhile, the unit detects pressure oscillations 

generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic 

pressure, and also pulse rate.

This Pro Cellular Blood Pressure Monitor CH-B2-11-AA is a digital monitor intended for 

use in measuring blood pressure and heartbeat rate with arm circumference ranging from 

22  to 42 cm (or 22 to 45 cm). It is intended for adult.

Comfortable Fabric Cuff

4

3

Integrated with 

Carbon App

Type BF applied part

Direct Current

General symbol for recovery/recyclable

Humidity limitation

Temperature limit 

Serial Number

MR Unsafe

To identify an item which poses unacceptable risks to the patient, 

medical staf for other persons within the MR environment. 

Caution

Indicates that caution is necessary when operating the device or control close 

to where the symbol is placed, or that the current situation needs awareness 

or operator action in order to avoid undesirable consequences. operator  

The symbol indicates that the product should not be discarded as unsorted waste 

but must be sent to separate collection facilities for recovery and recycling. 

Refer to instruction manual/booklet. 

Consult instructions for use or 

consult electronic instructions for use

Class II Equipment

For indoor use only

Batch code

Polarity of d.c. power

connector

Manufacturer

Date of manufacture

Atmospheric pressure limitation 

One-click Operation

Large 3.5 inch LCD

Display

View Result History in App

Summary of Contents for Carbon Health CH-B1-11-AA

Page 1: ...1 0 Guangdong Transtek Medical Electronics Co Ltd Zone A No 105 Dongli Road Torch Development District 528437 Zhongshan Guangdong China User Manual Blood Pressure Monitor Bluetooth Connected Model CH...

Page 2: ...pressure and diastolic pressure What is the standard blood pressure classi cation Why does my blood pressure fluctuate throughout the day Why do i get a different blood pressure at home compared to t...

Page 3: ...e and also pulse rate This Pro Cellular Blood Pressure Monitor CH B2 11 AA is a digital monitor intended for use in measuring blood pressure and heartbeat rate with arm circumference ranging from 22 t...

Page 4: ...s component part lists descriptions and calibration procedures will be made available by the manufacturer or distributor This device is intended for indoor use This device is portable but it is not in...

Page 5: ...ation and air leakage testing at least at 50 mmHg and 200 mmHg Warning Do not use the device while under maintenance or being serviced Store your device cuff and adapter in a clean and dry place prote...

Page 6: ...ou nish the measurement 5V 1A Replace the batteries whenever the below happens The low battery symbol appears on the display When any button is pressed and nothing is displayed on the screen BATTERY C...

Page 7: ...oth and the Carbon Health App Make sure both are ON when pair up is proceeding 3 When the monitor is OFF press and hold the START STOP button unitl the symbol appears on the LCD and blink indicating p...

Page 8: ...o insert one nger between the cuff and your arm 2 3 cm 1 inch MEASUREMENT Interference may occur in the vicinity of equipment marked with the following symbol And CH B1 11 AA may interfer the vicinity...

Page 9: ...nd the oldest record will drops from the list after the measurement Caution You can either record your measurement results manually along with the time of measurement or transfer them electronically t...

Page 10: ...d avoid the sunshine Avoid intense shaking and collisions Use a damp cloth to remove dirt Avoid washing the cuff Avoid dusty and unstable temperature environments Within 20 minutes after taking a bath...

Page 11: ...e Please contact a physician if your measurement falls out of the range Please note that only a physician can tell whether your blood pressure value has reached a dangerous point The following chart i...

Page 12: ...for 4 5 minutes to calm down If the cuff is tied properly If the cuff is too tight or too loose If the cuff is tied on the upper arm If you feel anxious 22 21 PROBLEM SYMPTOM CHECK THIS REMEDY No pow...

Page 13: ...e value 40 199 beat minute Device Classi cation Expected Lifetime Battery Powered Mode Internally Powered ME Equipment AC Adaptor Powered Mode Class II ME Equipment Temperature 5 C to 40 C Relative hu...

Page 14: ...s RF emissions CISPR 11 RF emissions CISPR 11 Group 1 Class B Class A Comply Compliance Harmonic emissions IEC 61000 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 Emissions test Table 2 EMC...

Page 15: ...modi cations not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the li...

Reviews: