EIS-LCD, EIS-40
USER MANUAL
Page 23
8.8
OUTPUTS SETTINGS
The behavior on the outputs is defined in the
Output tab.
Figure 14: WEB Server-Output setting
Output 1- Settings for output 1:
•
Output (relay) mode:
User can select between 3 options
Disable
-Output is disabled
Latching
-Output is in latching mode. First Caller ID or PIN entry will activate the output,
second Caller ID or PIN entry will deactive the output.
Time Pulse
-Output is time pulse mode. After output is triggered it will be activated for the
time defined in
Output pulse duration
, after that time output will be restored.
•
Output pulse duration:
ON time for output in case of output mode
Timer pulse.
•
Output is:
Output can work in normal or inverted (normally close) mode.
Normally open-
In idle mode output pins are in open position.
Normally closed-
In idle mode output connection are closed.