background image

Transition Networks 

 

 

 

     

               

TN-SFP-xx25G-xR-S Series User Guide 

33815 Rev. A 

                              

https://www.transition.com/ 

Page 7 of 9 

DDMI (Digital Diagnostics Monitoring Interface) 

DDMI (Digital Diagnostics Monitoring Interface) provides enhanced digital DMI for optical transceivers which 
allows real time access to device operating parameters. 
The following DMI port screen and explanation table contains brief definitions of the DDMI support offered on 
some Small Form Factor Pluggable (SFP) Transceiver Modules. For further information, see the help option or 
User Guide for the relate product4. 

Note: 

This feature is not available on all devices and may vary between 

products. See the related manual for more information.  

 

The Transceiver Information and DDMI Information sections are described below.  

  DDMI Parameter

 

                                        Description 

DMI 

Rx Power (uW) Intrusion Threshold; a level for Rx Power on the Fiber port. If the DMI 
read value falls below the preset value, an intrusion is detected, and a trap is 
generated. The default is 0 uW. The range is 0 - 65,535 uW. 

Port 

The device’s port number. 

 

Vendor 

The SFP vendor’s name (e.g., 

Transition

). 

Part

 

Number 

The SFP vendor Part number provided by the SFP vendor (

TN-10GSFP-SR

). 

Serial

 

Number 

The SFP Vendor Serial number provided by the SFP vendor (e.g., 

8672105

). 

Revision 

The SFP vendor Revision level for part number provided by the SFP vendor. 

Date

 

Code 

The vendor's manufacturing date code (e.g

., 2011-08-09

). 

Transeiver 

The Transceiver compatibility (e.g., 

1000BASE_SX

 or 

10G

). 

Current 

The current value of temperature, voltage, TX bias, TX power, and RX power.  

High Alarm Threshold 

The high alarm threshold value - temperature, voltage, TX bias, TX power, - RX power.  

High Warn Threshold 

The high warn threshold value of temperature, voltage, TX bias, TX power, RX power.  

Low Warn Threshold 

The low warn threshold value of temperature, voltage, TX bias, TX power, RX power.  

Low Alarm Threshold 

The low alarm threshold value - temperature, voltage, TX bias, TX power, RX power. 

Summary of Contents for TN-SFP Series

Page 1: ...andards 2 Optical Specifications 3 Applications 3 SFP Unpacking 3 SFP Installation 3 Cautions 3 Installing an SFP Module 3 Fiber Cable Physical Characteristics 4 Connecting Fiber Cables 4 Removing an...

Page 2: ...se RRHs must be connected to baseband units sitting at centralized locations The connection between the RRUs and the base station is often called fronthaul While 4G LTE uses CPRI Common Public Radio I...

Page 3: ...s into the fiber bore of the SFP transceiver module as this will cause the optics to not operate properly Clean the optic surfaces of the optical fiber before you plug them back in to the optical bore...

Page 4: ...future use 10 Attach an appropriate cable into the SFP module port 11 Attach the other end of the cable into the other device 12 Observe the status LED s See the related manual for details Fiber Cable...

Page 5: ...eases the SFP transceiver module from the socket connector Grasp the actuator button between your thumb and index finger and carefully pull the SFP transceiver module straight out of the module slot b...

Page 6: ...t Measured transmit bias current in microamperes DMI Bias Alarm Alarm status for measured transmit bias current for the interface DMI Tx Power Measured transmit power in microwatts and in decibels rel...

Page 7: ...port If the DMI read value falls below the preset value an intrusion is detected and a trap is generated The default is 0 uW The range is 0 65 535 uW Port The device s port number Vendor The SFP vendo...

Page 8: ...g foa htm Compliance Information Class I Laser Compliance This product has been tested and found to comply with the limits for FDA Class I laser for IEC60825 EN60825 and 21CFR1040 specifications Trans...

Page 9: ...il of 27 January 2003 Transition Networks will accept post usage returns of this product for proper disposal The contact information for this activity can be found in the Contact Us portion of this do...

Reviews: