Unit “freezes”.
RI, RO switches are
Set unconnected port
in passive position
switch to “A”(active)
but one port is not
position.
connected.
ZDL disabled and
Switch ZDL to ON
wrong speed station and reset hub.
tries to insert.
RI or RO cable
Replace cable.
broken while in
“Passive” position.
Cannot manage
Stack initialization
Reset Stack (See 5.2
stack
Incorrect Replace
cable.
management cable
used.
Table 5-1. Fault Isolation in the StackMaster™TR 16-Port Stack