3
3.. IIN
NSST
TA
ALLLLA
AT
TIIO
ON
N
3-11
USER’S GUIDE
SNMP Parameters
To set the SNMP parameter values:
1.
To access the SNMP Parameters Menu, at the Network
Parameters MAIN> prompt, type and enter:
MAIN> snmp
The StackMaster™TR 16-Port SNMP Parameters Menu comes up to
provide guidance in setting parameters for data to be used by the external
SNMP network management software:
2.
Referring to the Site Configuration Data Sheet, type and enter
modified configuration values in the format:
SNMP> <parameter> = <value>
3.
Verify the modified configuration values by bringing up the same
menu:
MENU> snmp
The menu is redisplayed with the modified values.
3.
Save the configuration values by typing and entering the
following
SNMP> save
SNMP> restart
SNMP> quit
The StackMaster™TR 16-Port restarts and the parameter values entered
are written to non-volatile memory.
SNMP Parameters Menu
commwrite
= PRIVATE
commread
= PUBLIC
auth
= DISABLE
trap
= 0.0.0.0
sysname
= NONE
contact
= NONE
location
= NONE
SNMP >