
3.4
Connecting StackMaster™TR to Token Ring
Network
When NO connection to RI port:
• ALWAYS set Ring In switch to Active position.
NOTE: The INSERT LED should remain OFF.
When NO connection to RO port:
• ALWAYS set Ring Out switch to Active position.
NOTE: The NORMAL LED should remain OFF.
When adding passive hub to RI port:
• Connect cable between StackMaster™TR RI and
RO of the passive hub
•
Set Ring In switch to Passive position.
When adding passive hub to RO port:
• Connect cable between StackMaster™TR RO and
RI of the passive hub
•
Set Ring Out switch to Passive position.
When removing passive hub from RI port:
• Set Ring In switch to Active position
•
Disconnect cable between StackMaster™TR RI
and RO of the passive hub.
When removing passive hub from RO port: • Set “Ring Out” switch to Active position
•
Disconnect cable between StackMaster™TR RO
and RI of the passive hub.
When interfacing to other manufacturers’ hub: The StackMaster™TR 16-Port is fully tested for
interoperatbility with other manufacturers’
concentrators that are compliant with 802.5
standards. Ensure that the RI/RO configuration of
the manufacturers’ concentrators functions with
the StackMaster™TR 16-Port.
3
3.. IIN
NSST
TA
ALLLLA
AT
TIIO
ON
N
3-5
USER’S GUIDE
Summary of Contents for STACKMASTER TR SMHB-TR-16
Page 1: ...StackMaster TR Active Retiming Managed Hub SMHB TR 16 7361 C...
Page 6: ......
Page 14: ......
Page 32: ......
Page 42: ...5 10 StackMaster TR...
Page 44: ......
Page 46: ......
Page 48: ......
Page 50: ......
Page 52: ......