![Transition Networks SPSVT26xx-10x User Manual Download Page 7](http://html1.mh-extra.com/html/transition-networks/spsvt26xx-10x/spsvt26xx-10x_user-manual_1151390007.webp)
12
SPSVT26xx-10x
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Technical Specifications
For use with Transition Networks Model SPSVT26xx-10x or equivalent.
Data Rate:
1.2 Kb/s to 10 Mb/s
Dimensions:
3.25" x 1.0" x 4.8"
(82mm x 25mm x 122mm)
Weight:
10 oz.
(283 g)
approximately
Power Consumption:
5.0 Watts
MTBF
(w/power supply)
:
41,660 hours
(MIL-HDBK-217F)
114,580 hours
(Bellcore)
Power Supply:
12.25VDC @ 1.0A, 100-240 VAC
(~1.0A)
, 15W max
Environment:
Tmra*:
0 to 50°C
(32 to 122°F)
Storage Temperature:
-15 to 65°C
(5 to 149°F)
Humidity:
10 to 90%, non condensing
Warranty:
Lifetime
*Manufacturer’s rated ambient temperature.
The information in this user’s guide is subject to change. For the most up-to-date
information on the SPSVT26xx-10x Device, see the user’s guide on-line at
www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or
view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
13
[email protected] -- Click the “Transition Now” link for a live Web chat.
Troubleshooting
If the Device fails, isolate and correct the fault by determining the answers to the
following questions and then taking the indicated action:
1.
Is the PWR LED on the Device illuminated?
NO
•
Is the power adapter the proper type of voltage and cycle frequency for the
AC outlet?
•
Is the power adapter installed in the Device and in the outlet?
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Is the CL LED on the Device illuminated?
NO
•
Are the copper cables connected properly?
•
Is the device attached to the Device via the copper cable working properly?
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 3.
3.
Is the FL LED on the Device illuminated?
NO
•
Check the fiber cables for proper connection.
•
Verify that the TX and RX cables on the Device are connected to the RX and
TX ports, respectively, on the other device.
•
Are both Devices
(connected via the fiber cables)
in the same mode
(synchronous or asynchronous)?
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 4.
4.
Are the CL and FL LEDs on the Device flashing
(indicating loop-back
mode)
?
NO
•
Disable the loop-back function. In hardware mode, set the loop-back switch
to NORM
(normal)
. In software mode, click “disable” in the loop-back
function.
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 5.
5.
Is data transfer failing?
YES
•
Are the clock input and output polarity correct?
•
Are the correct copper cables installed for the data format?
•
Is the mode on the other device correct
(synchronous/asynchronous)
?
•
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
No
•
Proceed to step 6.