Transition Networks SPSVT26xx-10x User Manual Download Page 6

10

SPSVT26xx-10x

24-hour Technical Support: 1-800-260-1312   International: 00-1-952-941-7600

Cable Specifications

Fiber Cable 

Bit Error Rate:  

<10-9

Single mode fiber

(recommended)

:

9 µm 

Multimode fiber 

(recommended)

:

62.5/125 µm 

Multimode fiber 

(optional)

:  

100/140, 85/140, 50/125 µm 

SPSVT2611-100

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

SPSVT2613-100

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

SPSVT2614-100 

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

SPSVT2615-100

1310 nm single mode

Fiber Optic Transmitter Power:

min: -8.0 dBm

max: -2.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

26.0 dB

SPSVT2629-100 

1310 nm (TX) / 1550 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

SPSVT2629-101 

1550 nm (TX) / 1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

SPSVT2629-102 

1310 nm (TX) / 1550 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

25.0 dB

SPSVT2629-103 

1550 nm (TX) / 1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

25.0 dB

The fiber optic transmitters on this device meet Class I Laser safety requirements per
IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.

[email protected] -- Click the “Transition Now” link for a live Web chat.

11

Cable Specifications 

— Continued

Copper Cable 

Copper twisted-pair, 28 AWG, 120 Ohm, 12 pf/foot capacitance 

(max)

Nominal DC resistance: 65.0 ohms per 1000 feet

(each conductor)

Shield type: Aluminum Foil-Polyester Tape/Braid Shield with drain wire

Standard Cable length: 3 m 

(10 ft.)

The five high-speed serial cables 

(available from Transition Networks)

that are

compatible with the 26-pin copper port on the SPSVT26xx-10x Device are the
following:

RS-232

RS-449

V.35

X.21

RS-530

Note: 

Please refer to the cable specifications documentation on-line at
www.transition.com.

Summary of Contents for SPSVT26xx-10x

Page 1: ...Contact Us 15 Compliance Information 16 Part Number Port One Copper Port Two Duplex Fiber Optic SPSVT2611 100 Universal 26 pin serial interface ST 1300 nm multimode 2 km 1 2 miles SPSVT2613 100 Unive...

Page 2: ...ckets 4 0 in 102 mm WMBV Optional Vertical Mount Bracket 5 0 in 127 mm WMBD Optional DIN Rail Mount Bracket 5 0 in 127 mm WMBD F Optional DIN Rail Mount Bracket flat 3 3in 84 mm Cable Options Supporte...

Page 3: ...A 1544 Kb s 3 112 Kb s B 2048 Kb s 4 128 Kb s C 3072 Kb s 5 256 Kb s D 4096 Kb s 6 384 Kb s E 6144 Kb s 7 512 Kb s F Asynchronous Mode techsupport transition com Click the Transition Now link for a l...

Page 4: ...example a local CPSVT2611 100 Device that is installed in a managed Transition Networks PointSystem chassis is connected via fiber to a remote SPSVT2611 100 Device An example of a managed single fiber...

Page 5: ...ve this caution could cause data transfer to fail 3 Connect the other end of the high speed serial cable to the other network device cable router CSU etc RX TX TX RX Device Device techsupport transiti...

Page 6: ...2629 101 1550 nm TX 1310 nm RX simplex Fiber optic Transmitter Power min 13 0 dBm max 6 0 dBm Fiber optic Receiver Sensitivity min 32 0 dBm max 3 0 dBm Link Budget 19 0 dB SPSVT2629 102 1310 nm TX 155...

Page 7: ...ers to the following questions and then taking the indicated action 1 Is the PWR LED on the Device illuminated NO Is the power adapter the proper type of voltage and cycle frequency for the AC outlet...

Page 8: ...e p p o C r e b i F r e p p o C Local Device Remote Device r e p p o C r e b i F r e p p o C Remote Device Local Device Declaration of Conformity Name of Mfg Transition Networks 10900 Red Circle Drive...

Page 9: ...s ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F ll ist der Benutzer f r Gegenma nahmen verantwortlich Attention...

Reviews: