Transition Networks
SPOEB10xx-105 User Guide
33618 Rev. C
https://www.transition.com/
Page
11
of
16
Technical Specifications
For use with Transition Networks SPOEB10xx-100 or equivalent.
Standards
IEEE 802.3, IEEE 802.3af
Data Rate
10/100 Mbps
Max Frame Size
1600 bytes (with or without VLAN tag)
Mac Addresses
2K
Dimensions
3.25" x 1” x 4.8" (82 mm x 25.4mm x 120mm)
Weight
Device: 0.8 lbs. [362 g] approx. Package: 2 lbs. [0.90 kg].
Power Consumption
25 Watts
Power Supply
External Isolated Class II 30W Power Supply: 90 – 250 VAC (TN# 25072)
Environment Tmra
0° to 40°C (32° to 104°F) (Manufacturer’s rated ambient operating temperature)
Storage Temp.
-25° to +85°C (-13° to +185°F)
Humidity
5% to 95%, non-condensing
Altitude
0 to 10,000 feet
MTBF
49,981 MIL217F2 Hours; 132,144 Bellcore Hours
*
Compliance
EN55022:1994+A1:1996+A2:1997 Class A, FCC Part 15 Subpart B, UL 1950
Warranty
Lifetime
Note
: The information in this user’s guide is subject to change. For the most up-to-date information on the
SPOEB10xx-100 media converter, view the user’s guide on-line at:
https://www.transition.com
.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of
manufacture.
WARNING: Visible and invisible laser radiation when open. Do not stare into the beam or view the beam directly with optical
instruments. Failure to observe this warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein may result in
hazardous radiation exposure.
WARNING: If the media converter is an IEEE802.3-2005 Powered Device (PD) capable of receiving power via the Media
Dependent Interface (MDI) leads, the power source, connector, and cabling attached to the barrel power connector must meet
the isolation requirement specified in IEEE802.3-2005. Failure to observe this warning could result in an electrical shock.
IMPORTANT Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video
Coax, etc., are intended to be connected to intra-building (inside plant) link segments that are not subject to lightening
transients or power faults. Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1,
DS3, Video Coax, etc., are NOT to be connected to inter-building (outside plant) link segments that are subject to lightening
transients or power faults. Failure to observe this caution could result in damage to equipment.
*
MTBF is estimated using the predictability method. This method is based on MIL-217F at 25°C ambient temperature, typical
enclosure heat rise of 10°C, and nominal operating conditions and parameters. Installation and configuration specific MTBF
estimates are available upon request. Contact Technical Support.