background image

Transition Networks 

 

SM12DP2XA Quick Start Guide

 

33750 Rev. D 

                                   

https://www.transition.com

   

Page 

2

  of 

2

 

RST (Reset) Button

: press and hold for 2-7 seconds to reset or 7-12 seconds to restore to factory defaults: 

Task   

Press RST button for 

SYS LED Behavior 

Port Status LED Behavior 

Reset the Switch 

2 ~ 7 seconds 

Blinking Green 

All LEDs OFF 

Restore to Defaults 

7 ~ 12 seconds 

Blinking Green 

All LEDs stay ON 

Mounting

: Mount the switch in a standard 19-inch equipment rack, on a desktop, or shelf; see the 

Install Guide

Cabling

: Make sure that the cables are suitable for your operating environment. For fiber optic connections, use 

50/125 or 62.5/125 micron multimode fiber or 9/125 micron single-mode fiber. For copper connections, use UTP 
for RJ-45 connections. For 1G bps connections use Category 5, 5e, 6, or 6a. 

Connecting to Power

: The SM12DP2XA front panel has two power inputs for power 

redundancy; the switch has a 100~240 VAC power socket for AC power Input and a 
24-48 VDC power input via the terminal block. Using both Power Supplies provides 
power failover when power supplies are connected to different circuits to. With fiber 
and copper cabling completed, and AC and/or DC power applied, the port LEDs light, 
the 

SYS

 LED flashes, the AC and/or DC LEDs light and the 

SYS

 LED goes from flashing 

to steadily lit. See the 

Install Guide

 for Connecting to an AC and/or DC Power source. 

Initial Switch Configuration

: Initial switch configuration can be via CLI or web browser. The factory defaults are 

IP Address: 

192.168.1.77

, User Name: 

admin

, and Password: 

admin

.   

CLI Configuration

: The command-line interface (CLI) is a text-based interface 

that you can access the CLI through either a direct serial connection to the 
device or a Telnet session. An RJ-45 cable is used for connecting a terminal or 
terminal emulator to the SM12DP2XA RJ-45 port to access the CLI. Attach the 
RJ-45 serial port on the switch front panel to the cable for Telnet/CLI 
configuration. Attach the other end of the DB-9 cable to a PC running Telnet. 
See the 

CLI Reference

 for initial switch configuration via CLI. 

Web UI Configuration

: The left-hand menu contains two main tabs (Switch and 

DMS) each with several sub-

tabs for configuring and monitoring the switch’s 

major functions. The major Switch tab functions include System, Ports, DHCP, 
Security, VLAN, QoS, Diagnostics, and Maintenance. The DMS (Device 
Management System) functions are DMS Mode, Graphical Monitoring, 
Management, and Maintenance. See the 

Web User Guide

 for initial switch 

configuration via web browser. 

Related Information

: Related manuals include the

 SM12DP2XA Install Guide

 33751, 

Web User Guide

 33752, and 

CLI Reference

 33753. For Drivers, Firmware, etc. go to the 

Product Support 

webpage (logon required).   

For Manuals, Brochures, Data Sheets, etc. go to th

Support Library 

(no logon required). For SFP manuals

 

see 

Transition Networks

 

SFP webpage

See

 

the

 

DC Power Supply

 

page for more information.

 

Contact

: Transition Networks | 10900 Red Circle Drive | Minnetonka, MN 55343 USA | 

tel: +1.952.941.7600 | toll free: 1.800.526.9267 | fax: 952.941.2322 | 

[email protected]

 

|

 

[email protected]

 

|

 

[email protected] 