System Log Configuration interface
Event Configuration
User can select the system log events. When selected events occur, the system will send out the log
information. Also, per port log events can be selected.
•
System event selection:
4 selections – Device cold start, Power status, SNMP Authentication
Failure, and X-Ring topology change. Mark the checkbox to select the event. When selected
events occur, the system will produce the logs
Device cold start:
When the device executes cold start action, the system will produce
a log message
Power status:
When the device power status has changed, the system will produce a
log message
SNMP Authentication Failure:
When the SNMP authentication fails, the system will
produce a log message
X-Ring topology change:
When the X-Ring topology has changed, the system will
produce a log message.
•
Port event selection:
Select the per port events. Per port have 3 selections – Link UP, Link
Down, and Link UP & Link Down. Disable means no event is selected.
Link UP:
The system will produce a log message when port connection is up only
Link Down:
The system will produce a log message when port connection is down only
Link UP & Link Down:
The system will produce a log message when port connection is
up and down