Transition Networks SAPTF33 series User Manual Download Page 5

8

SAPTF33xx-1xx 

24-hour Technical Support:

1-800-260-1312

-- International:

00-1-952-941-7600

Installation 

-- Continued

Installing the Cable -- Automatic Ring-Down Configuration

NOTE:

Both Unit B’s MUST be configured for Automatic Ring-Down (see page 4).

Fiber

1.

Locate or build fiber cable with male, two-stranded TX to RX connectors
installed at both ends.

2.

Connect the fiber cables to the 

first Unit B

(SAPTF33xx-110) as described:  

Connect the male 

TX

cable connector to the female 

TX

port.

Connect the male 

RX

cable connector to the female 

RX

port.

3.

Connect the fiber cables to the 

second Unit B

(SAPTF33xx-110) as

described:  

Connect the male 

TX

cable connector to the female 

RX

port.

Connect the male 

RX

cable connector to the female 

TX

port.

Copper

1.

Locate or build copper cables with male, RJ-11C connectors installed at
both ends.

2.

Connect the copper cables to 

both Unit B

’s (SAPTF33xx-110) as described:  

Connect the RJ-11C connector at one end
of the cable to the RJ-11C port on the

first Unit B

.

Connect the RJ-11C connector at the
other end of the cable to the RJ-11C port

on the telephone device

.

3.

Connect the copper cables to the 

second Unit

B

(SAPTF33xx-110) as described in step 2.  

TX

RX

ACT

SDF

PWR

TX

RX

ACT

SDF

PWR

Connect to the 

RJ-11C port on the

telephone device.

Unit B

Unit B

Unit B

9

[email protected]

Click the “

Transition Now

” link for a live Web chat.

Operation 

Power the Media Converter 

NOTE:

The external power supply provided with this product is UL listed by

the power supply’s manufacturer.

AC

1.

Install the barrel connector of the AC power cord to the external power
connector on back of the media converter.

2.

Connect the AC power cord to the correct voltage AC rack or wall socket.  

3.

Verify that the media converter is powered by observing the illuminated
LED power indicator light.

DC

Consult the user’s guide for the Transition Networks SPS1872-xx DC external
power supply for powering the media converter.

Status LEDs

Use the status LEDs to monitor the SAPTF33xx-1xx media converter operation
in the network.  

PWR (Power)

On = The media converter is connected to external power.

SDF (Signal Detect Fiber Link)

On = The fiber link is active.

ACT (Activity)

On = The telephone device is in use (off-hook).

Flashing = The telephone device is ringing or pulse-dialing.

T

ACT

SDF

PWR

Summary of Contents for SAPTF33 series

Page 1: ...d automatic ring down Two units are required to implement an end to end system An RJ 11 female connector provides the electrical interface between the media converter and the telephone device NOTE The...

Page 2: ...in pairs The table below lists which models should be installed in the same network for the standard configuration see page 4 3 techsupport transition com Click the Transition Now link for a live Web...

Page 3: ...r to the media converter and carefully remove the cover 2 Locate the jumpers on the circuit board 3 Using small needle nosed pliers or similar device move the jumper to the desired position Refer to t...

Page 4: ...hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 3 4 inch spacing Grounding lugs 6 32 1 8 diam 12 AWG copper wire not included Star washer included Lug nuts included Two hole comp...

Page 5: ...able to the RJ 11C port on the telephone device 3 Connect the copper cables to the second Unit B SAPTF33xx 110 as described in step 2 TX RX ACT SDF PWR TX RX ACT SDF PWR Connect to the RJ 11C port on...

Page 6: ...11 techsupport transition com Click the Transition Now link for a live Web chat Cable Specifications The physical characteristics must meet or exceed FCC part 68 specifications Copper Cable Category...

Page 7: ...Connector Specification Unit A Telephone Emulation Connector RJ 11C Impedance 600 REN 0 4 B Loop Current 10 to 100 mA Insertion Loss 0 0 1 0 dB at 1000 Hz When both ports are terminated at 600 Unit B...

Reviews: