Transition Networks SAPTF33 series User Manual Download Page 3

4

SAPTF33xx-1xx

24-hour Technical Support:

1-800-260-1312

-- International:

00-1-952-941-7600

SAPTF33xx-1xx in the Network

Standard Configuration

One Unit A device (SAPTF33xx-100) and one Unit B device (SAPTF33xx-110)
are required for the standard configuration.  The Unit A device is connected to
the Central Office (CO) while the Unit B device is connected to a telephone
device.

Automatic Ring-Down Configuration

Automatic Ring Down (ARD) is a dedicated, point-to-point voice system.  When
one telephone is taken off-hook, the other telephone rings, without the need to
dial.  Two Unit B devices (SAPTF33xx-110), connected via the fiber ports, are
required for this mode of operation; with a telephone device at each end.  

SAPTF33xx-100

Unit A -- Emulates 
the telephone device

SAPTF33xx-110

Unit B -- Emulates the

Central Office (CO)

Central Office (CO)

SAPTF33xx-110

Unit B -- Emulates the 
Central Office (CO)

SAPTF33xx-110

Unit B -- Emulates the

Central Office (CO)

5

[email protected]

Click the “

Transition Now

” link for a live Web chat.

Installation 

CAUTION:  Wear a grounding device and observe electrostatic discharge
precautions when setting the jumpers.  Failure to observe this caution could
result in damage to, and subsequent failure of, the media converter.

Setting the Jumpers

1.

Using a small screwdriver, remove the screws that secure the cover to the
media converter and carefully remove the cover.

2.

Locate the jumpers on the circuit board.

3.

Using small needle-nosed pliers or similar device, move the jumper to the
desired position.  (Refer to the drawings below.)

4.

Carefully replace the cover on the media converter and replace the
screws to secure the cover.

Standard / Automatic Ring-Down

The jumper labeled “JP1” is used to switch between the Standard or Automatic
Ring-Down configuration and is located on the 

top 

circuit board of 

Unit B

(SAPTF33xx-110)

.  

The drawing below illustrates the jumper settings.    

Set jumper JP1 on the Unit B device to the 

Standard

setting when

using the Standard configuration (described on page 4).

Set jumper JP1 on 

both

Unit B devices to the 

Automatic Ring-Down

setting when using the Automatic Ring-Down configuration
(described on page 4).

US / EU Telephone Regulation

The jumper labeled “US  EU” is used to switch between the US or EU
telephone configuration and is located on the 

top 

circuit board of 

Unit A

(SAPTF33xx-100)

.  This feature is required to comply with the EU TBR21

telephone regulation.  The jumper has been set at the factory to the US setting
as the default.  

The drawing below illustrates the jumper settings.  

Set jumper “US  EU” on the Unit A device to the 

US

setting if the

device is to be used with US-based telephone systems.

Set jumper “US  EU” on the Unit A device to the 

EU

setting if the

device is to be used with European-based telephone systems.

Standard

1

3

Automatic

Ring-Down

1

3

JP1

JP1

US Setting

EU Setting

US

EU

US

EU

Summary of Contents for SAPTF33 series

Page 1: ...d automatic ring down Two units are required to implement an end to end system An RJ 11 female connector provides the electrical interface between the media converter and the telephone device NOTE The...

Page 2: ...in pairs The table below lists which models should be installed in the same network for the standard configuration see page 4 3 techsupport transition com Click the Transition Now link for a live Web...

Page 3: ...r to the media converter and carefully remove the cover 2 Locate the jumpers on the circuit board 3 Using small needle nosed pliers or similar device move the jumper to the desired position Refer to t...

Page 4: ...hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 3 4 inch spacing Grounding lugs 6 32 1 8 diam 12 AWG copper wire not included Star washer included Lug nuts included Two hole comp...

Page 5: ...able to the RJ 11C port on the telephone device 3 Connect the copper cables to the second Unit B SAPTF33xx 110 as described in step 2 TX RX ACT SDF PWR TX RX ACT SDF PWR Connect to the RJ 11C port on...

Page 6: ...11 techsupport transition com Click the Transition Now link for a live Web chat Cable Specifications The physical characteristics must meet or exceed FCC part 68 specifications Copper Cable Category...

Page 7: ...Connector Specification Unit A Telephone Emulation Connector RJ 11C Impedance 600 REN 0 4 B Loop Current 10 to 100 mA Insertion Loss 0 0 1 0 dB at 1000 Hz When both ports are terminated at 600 Unit B...

Reviews: