background image

FAULT ISOLATION and CORRECTION

If the PSM-8E fails, isolate and correct the fault by determining the answers to
the following questions and then taking the indicated action:

1.

Is the PSM-8E Power LED illuminated?
NO

Is the LED on top of the external PSM-8E power supply illuminated?

Is the power cord properly installed in the PSM-8E and in the
grounded AC outlet?

Does the grounded AC outlet provide power?

Contact Technical Support: (800) 260-1312.

YES

Continue at step 2.

2.

Is the PSM-8E RX LED OFF or FLASHING?
YES

Are the fiber-optic connectors are properly connected?

Have the fiber-optic budget and distance been exceeded?

NO

Continue at step 3.

3.

Is the PSM-8E TX LED OFF?
YES

If problems persists, contact TRANSITION Networks Technical
Support.

NO

Continue at step 4.

4.

Is a network device down or unstable?
YES

Is there one and only one host polling group per PSM-8E polling
group?

Does the host device type match the device?

Has the  host work station controller (WSC) capacity been
exceeded?

Is the device properly terminated using two 54.9 ohm resistors
located between the "A" phase pin & earth ground and the "B" phase
pin & earth ground? NOTE: Termination is provided by a "Y" or "T"
cable assembly or by a terminating balun (i.e. ASFT series).

Are there polarity reversals in the cable?

Does the cable distance exceed the PSM-8E specification?

Is the cable data grade?

Does the wiring use natural pairs?

Does the wiring avoid sources of environmental noise?

Does the balun pinout match the PSM-8E ’s pinout?

Does the pinout/polarity of the host side balun match the
pinout/polarity of the device side balun?

NO

Continue at step 5.

Install PSM-8E at Site

WARNING: During the site installation, handle the PSM-8E in such a way
that the PSM-8E does not fall. Failure to observe this warning could result in
injury to personnel and/or equipment damage.

NOTE: If PSM-8E is shipped with brackets installed, proceed to step 2.

To install the PSM-8E in 19-inch rack cabinet:

1.

Remove and retain two (2) screws located at front left side and front
right side of PSM-8E chassis. Install right and left front brackets
(provided) on chassis by installing two (2) retained screws through
each bracket into chassis.

2.

Carefully align PSM-8E between 19-inch rack mounting rails.

3.

Install PSM-8E by installing two (2) screws through right front
bracket into rack and two (2) screws through left front bracket into
rack, using clip nuts and nylon washers (NOT provided) to secure, if
necessary.

To install the PSM-8E on table or other flat surface:

NOTE: Rubber feet are provided.

1.

Carefully turn PSM-8E to side.

2.

Install four (4) rubber feet:

Separate rubber feet.

Remove protective
paper from
adhesive surface
on rubber foot.

Position and
secure each
rubber foot as shown.

3.

Return PSM-8E to upright position. 

1

3

2

PowerStar 

Express

 Multiplexer

Link

Status

TX

RX

PSM-8E

2X

2X

0

1

GROUP A

2X

2X

2

3

GROUP B

2X

2X

4

5

GROUP C

2X

2X

6

7

GROUP D

Summary of Contents for PSM-8E

Page 1: ...interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at th...

Page 2: ...polling groups ports 0 3 comprise one polling group and ports 4 7 comprise the other polling group TECHNICAL SPECIFICATIONS Protocol 5250 Data Rate 1 Mb s 2 Mb s transparent Number of Ports Eight 8 Ho...

Page 3: ...multimode fiber Optional 100 140 m multimode fiber 85 125 m multimode fiber 50 125 m multimode fiber Peak Power Wavelength 820 nanometers Typical Maximum Cable Distance Point to point Up to 2 kilomet...

Page 4: ...w reconfigure jumpers as required NOTE JUMPERS SETTINGS FOR ALL EIGHT 8 SETS OF JUMPERS MUST BE IDENTICAL 4 Replace PSM 8E top cover Carefully tilt top cover down Slide top cover forward to align agai...

Page 5: ...ata grade Does the wiring use natural pairs Does the wiring avoid sources of environmental noise Does the balun pinout match the PSM 8E s pinout Does the pinout polarity of the host side balun match t...

Page 6: ...er using either one or more of up to eight 8 shielded twisted pair cables with RJ 45 connectors and appropriate baluns OR using a single shielded DB 25 to DB 25 cable RJ 45 At Front At the front of th...

Page 7: ...e baluns for the RJ 45 pin configuration REMOTE CONTROLLER At the front of the host PSM 8E connect a remote controller to the host PSM 8E using two 4 port twinax bricks twisted pair copper cable with...

Page 8: ...TX and RX cable connectors at other end of cable to RX and TX female connectors respectively on device PSM 8E s OR at fiber optic patch panel TX TX RX RX TX TX RX RX Host Port Connections Host Multip...

Page 9: ......

Reviews: