28
CPSMC19xx-100 PointSystem
™
Chassis
chassis
4.2
Cascade Option
The management module cascade option allows the network administrator to con-
nect up to eight (8) CPSMC19xx-100 chassis into one manageable stack, providing
a single management source for up to 143 conversion devices.
To create the cascade option, the CPSMM-200 Dual Slot Master Management
Module is installed in the first chassis in the series. The CPSMM-210 Single-Slot
Expansion management module is installed in each subsequent chassis.
An alternative setup involves installing two CPSMM-200 Dual-Slot Master
Management Modules into two adjacent chassis for redundant management.
In this set-up, the two CPSMM-200 management modules auto-negotiate so that
one is the primary module while the other is in stand-by mode. If the primary
module fails, the stand-by module automatically takes over and manages the net-
work.
24-hour Technical Support:
1-800-260-1312
-- International:
00-1-952-941-7600
Pwr
RESET
Pwr
RESET
INIT
10BASE-T
RX
TX
LNK
PWR
RESET
DB-9
The CPSMM-200
management module is
installed in the first
chassis in the series
The CPSMM-210
management module is
installed in each
subsequent chassis
10BASE-T
RX
TX
LNK
PWR
RESET
DB-9
The CPSMM-200
management module is
installed in the first
chassis in the series
Another CPSMM-200
managment module is
installed in the next
chassis as a backup