Installation

Checklist

Before installing the N-FX module, verify that the package contains the following
items:

• N-FX module

• LAN driver CD

Please notify your sales representative if any item is missing or damaged.

Description

The N-FX module has a bootable ROM socket 

(ROM chip sold separately).

The

two LED indicators, LINK/ACT and FDX located on the bracket, show
network/board link, activities, collision, and full-duplex statuses. See Figure 1.

N-FX module installation

CAUTION: 

Wear a grounding strap and observe electrostatic discharge

precautions when installing the N-FX module. Failure to observe this caution
could result in damage or failure of the N-FX module.

N-FX Series Fast Ethernet NICs

2

Tech Support: 1-800-260-1312   International: 00-1-952-941-7600, 24 hours

LINK/ACT

LED

FDX LED

Boot ROM Socket

Figure 1: LEDs and Boot ROM Socket

To install the N-FX module, do the following:

Important:

Install the N-FX module in a “master slot” only. 

1.

Locate a master slot on the PC workstation or file server.

2.

Remove the cover from the PC workstation or file server—keep all screws.

3.

Remove and keep the screws holding the cover to the installation slot. 

4.

Carefully align to the slot guides and slide the N-FX module into the
“master slot.” 

Install the N-FX module -- continued

5.

Ensure that the module is firmly seated in the slot.

6.

Use the screws from step “3” to secure the module to the workstation or
file server housing. 

N-FX PCI module configuration

For motherboards with automatic PCI configuration: 

No specific setup is needed.

You can enter the system BIOS setup menu to view or specify the interrupt
(INT) line of the PCI slots.

For motherboards with bus master and interrupt jumpers:

Enable bus master operation in a selected PCI slot and select an INT
request line (IRQ) level, using the appropriate motherboard jumper.

Enable I/O on the N-FX, PCI slot.

PCI bus system and configuration

Ensure that the PCI machine supports master slots, and INT multiple
sharing and timing compatibility. 

DO NOT install N-FX in PCI slave slots. Please refer to your PC system
manual and select the appropriate configuration settings.

When installing multiple N-FX modules in a server station, you should
correctly configure the IRQ settings of the PCI slot. 

Up to four N-FX modules can be installed in a PCI file server running
NetWare operating system. 

N-FX server modules share the same INT line with the driver supporting
multiple INT services at a time. The IRQ of each N-FX module should not
conflict with other boards.

Operation in full or half-duplex 

(default)

mode is configured by LAN

driver options. The operating mode should match the working status of the
remote link device.

Use EMM386 version 4.49 or higher, and install both DOS and EMM386
from the same DOS package to avoid software problems.