background image

METTF1011

(-120 and -060)

Channel Speed

10 Mb/s

Fiber-Optic Ports

Cable:

Multimode fiber-optic

Connector Type

ST

Wavelength

850 nm

Transmitter Power

-15 dBm

Receiver Sensitivity

-32 dBm

Maximum Loss Budget

18 dB

Maximum distance

3 km (1.8 mi) full-duplex

Twisted-Pair Copper Ports

Cable 

Category (or better) copper

Connector Type

RJ-45

Maximum distance

100 meters (328 feet)

METTF1013

(-120 and -060)

Channel Speed

10 Mb/s

Fiber-Optic Ports

Cable:

Multimode fiber-optic

Connector Type

SC

Wavelength

850 nm

Transmitter Power

-15 dBm

Receiver Sensitivity

-32 dBm

Maximum Loss Budget

18 dB

Maximum distance

3 km (1.8 mi) full-duplex

Twisted-Pair Copper Ports

Cable 

Category (or better) copper

Connector Type

RJ-45

Maximum distance

100 meters (328 feet)

B.2

METTF10xx, MFETF10xx

Summary of Contents for METTF1011-060

Page 1: ...Multichannel Media Converter 33214 A METTF10xx MFETF10xx...

Page 2: ...rungen auftreten in weichen F llen der Benutzer f r entsprechende Gegenma nahmen werantwortlich ist Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er...

Page 3: ...e 2 4 2 3 1 Setting Management Module Jumper 2 4 2 3 2 Installing Power Supply Module 2 5 2 4 Installing Multichannel Media Converter at Site 2 6 2 4 1 Standard Rack Installation 2 6 2 4 2 Table Top I...

Page 4: ...ware at Remote NMS 3 6 4 MAINTENANCE 4 1 4 1 Fault Isolation and Recovery 4 2 4 2 Hardware Replacement Procedures 4 5 4 2 1 Replacing Management Module 4 5 4 2 2 Replacing AC Power Supply Module 4 6 A...

Page 5: ...ST or SC fiber connectors The Multichannel Media Converter can be installed as a standalone unit or in a standard rack and can be managed at an attached terminal or using an SNMP application at a remo...

Page 6: ...ir Ports IEEE802 3 compliant 10BASE T 100BASE TX twisted pair ports operate at 10Mb s or 100Mb s full duplex or half duplex Fiber Optic Ports IEEE802 3 compliant 10BASE FL 100BASE FX fiber optic ports...

Page 7: ...an ON OFF power switch Power is applied to and removed from the Multichannel Media Converter by connecting and disconnecting the power cord The Multichannel Media Converter rear panel also contains an...

Page 8: ...Steady LED indicates that the Management Module is receiving traffic through the PS 2 serial port or through the RJ 45 network port Ready Steady LED indicates that the Management Module is properly i...

Page 9: ...e at Remote NMS TRANSITION Networks Multiport Management Software allows remote management of the Multichannel Media Converter Clicking the Help button or the button at the Multiport Management Softwa...

Page 10: ......

Page 11: ...l Media Converter at Site 2 6 2 4 1 Standard Rack Installation 2 6 2 4 2 Table Top Installation 2 7 2 5 Powering the Multichannel Media Converter 2 8 2 6 Connecting Channel Ports to Network 2 9 2 6 1...

Page 12: ...er circuits or power stabilizers to supply reliable power to the Multichannel Media Converter Keep twisted pair cabling away from sources of electrical noise such as radios electric motors transmitter...

Page 13: ...the shipment Item Multichannel Media Converter Rack mounting kit Four self adhesive rubber feet Power Cord Management Control Cable Muliipoint Management Software Disk Redundant Power Supply Module w...

Page 14: ...ent failure of Management Module and or Power Supply Module NOTE Power Supply Modules can be hot swapped 2 3 1 Setting Management Module Jumper CAUTION Failure to set the Management Module NJP1 jumper...

Page 15: ...t the rear of the Multichannel Media Converter 2 Remove the protective plate from the Multichannel Media Converter by unscrewing two 2 thumbscrews that secure the protective plate to the Multichannel...

Page 16: ...nnel Media Converter 4 Repeat steps 3 and 4 for second mounting bracket 5 Locate four 4 screws not provided and optional clip nuts not provided for each Multichannel Media Converter to be installed 6...

Page 17: ...the Multichannel Media Converter Failure to observe this caution could cause Multichannel Media Converter to fail 1 Select a level secure surface in a well ventilated area 2 Remove the adhesive protec...

Page 18: ...g the two power cords to outlets on separate power circuits To power the Multichannel Media Converter through the AC Power Supply Module s 1 Locate Power Supply Module s at back of Multichannel Media...

Page 19: ...ly set CAUTION If any network devices connected to a channel are not capable of full duplex FDX then all other channel devices must be set to half duplex HDX INCLUDING THE MULTICHANNEL MEDIA CONVERTER...

Page 20: ...nk is cut Then the remote device senses loss of the fiber optic link and if the remote device is another Multichannel Media Converter also set to NORMAL mode the remote Multichannel Media Converter di...

Page 21: ...with installed fiber optic cable is illuminated indicating that a link exists between the fiber optic port on the Multichannel Media Converter and the network device connected to the channel port 5 Re...

Page 22: ...rameter values If necessary modify the attached terminal port parameter values 4 Start the terminal emulation program 5 Cycle power to the Multichannel Media Converter by disconnecting the power cord...

Page 23: ...should byte 5 be 82 SNMP PARAMETERS Get community public Set community private Trap destination 192 168 1 15 Trap community trap System name LAN System location location System Contact administrator...

Page 24: ...connecting the Multichannel Media Converter to TCP IP network management 2 Connect RJ 45 connector at one end of cable to Multichannel Media Converter RJ 45 twisted pair Management port 3 Connect RJ...

Page 25: ...d through the 10BASE T port to a TCP IP network that is accessible via IP from the network management station 2 At the network management station load the Multiport Management Software from the Multip...

Page 26: ......

Page 27: ...tor can monitor and manage the Multichannel Media Converter using an attached terminal or terminal emulator or at a remote Telnet connection The network administrator also can monitor and manage the M...

Page 28: ...orming a Link Test on the fiber optic ports Management LEDs LED Color Indicates LNK Steady Green A link is established between the Management Module and the connected network device REC Flashing Green...

Page 29: ...a Converter to the PC by connecting the miniDIN end of the control cable provided to the Multichannel Media Converter Management PS 2 port and the other end of the cable to the PC DB 9 serial port con...

Page 30: ...twisted pair and fiber optic link status test state and duplex mode as well as the status of the power supplies and the chassis temperature Port s status Channel TP Link FO Link Test FDX 01 OFF OFF OF...

Page 31: ...X control menu At the HDX control menu toggle selected channels between half duplex mode and full duplex mode Selecting one of the numbered options at the HDX control menu changes the duplex mode of t...

Page 32: ...s in the PROGRAMS menu The Multiport Management Software comes up and then prompts for the IP address of the METTF10xx or MFETF10xx Multichannel Meda Converter to be managed 2 Enter the IP address of...

Page 33: ...re of the device in degrees Celsius Poll Rate is the time interval in seconds that the application polls the managed device To change the Poll Rate enter a new integer value and press the Enter key Sy...

Page 34: ......

Page 35: ...enance direction for the TRANSITION Networks Multichannel Media Converter provided in this section includes 4 1 Fault Isolation and Recovery 4 2 4 2 Hardware Replacement Procedures 4 5 4 2 1 Replacing...

Page 36: ...ted securely to the Multichannel Media Converter MAIN power supply and to the power outlet Ensure that the MAIN power supply module is seated firmly in the Multichannel Media Converter Ensure that the...

Page 37: ...ON Ensure that the fiber optic cable is connected to the fiber optic port and to the network device Ensure that the network device connected to the fiber optic port is operating at correct speed 10 Mb...

Page 38: ...pear in the MIB browser Ensure that the Multichannel Media Converter MIB file is copied to the proper location in the remote Network Management Station Ensure that the MIBs are compiled with the new f...

Page 39: ...ed at the rear of the Multichannel Media Converter 3 Carefully remove the Management Module to be replaced from the Multichannel Media Converter by unscrewing two 2 thumbscrews that secure the Managem...

Page 40: ...be replaced from the Multichannel Media Converter by unscrewing two 2 thumbscrews that secure the Power Supply Module to be replaced to the Multichannel Media Converter 5 Carefully slide the replacem...

Page 41: ...sition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model Multichannel Media Converter Part Number MFETF1011 120 MFETF1013 120 MFETF1011 060 MFETF1013 060 METTF1011 120 METTF1013 120 METTF...

Page 42: ......

Page 43: ...ory 5 Gauge 24 to 22 AWG Attenuation 20 dB 1000 10 MHz 22 0 dB 100m 100 MHz Differential Characteristic Impedance 100 10 10 MHz NOTE The active pairs are pins 1 2 and pins 3 6 Use only dedicated wire...

Page 44: ...e Category 3 or better copper Connector Type RJ 45 Maximum distance 100 meters 328 feet METTF1013 120 and 060 Channel Speed 10 Mb s Fiber Optic Ports Cable Multimode fiber optic Connector Type SC Wave...

Page 45: ...r better copper Connector Type RJ 45 Maximum distance 100 meters 328 feet MFETF1013 120 and 060 Channel Speed 100 Mb s Fiber Optic Ports Cable Multimode fiber optic Connector Type SC Wavelength 1300 n...

Page 46: ......

Reviews: