2.7
Setting Network Management Parameters
CAUTION: IP parameters should be set and/or modified
ONLY
at the
attached terminal Interface.
To set the Multichannel Media Converter network parameters:
1.
Locate a PC equipped with any terminal emulation program.
2.
Connect the Multichannel Media Converter to the PC by
connecting the miniDIN end of the control cable (
provided
) to the
Multichannel Media Converter Management PS/2 port and the
other end of the cable to the PC DB-9 serial port connector.
NOTE: By default, the Multichannel Media Converter uses the
following serial port parameter values:
bits per second
9600
stop bits
1
data bits
8
parity
NONE
flow control
Xon/Xoff
3.
Using methods appropriate to the attached terminal, verify that
the serial port parameters of the attached terminal match the
Multichannel Media Converter port parameter values. If
necessary, modify the attached terminal port parameter values.
4.
Start the terminal emulation program.
5.
Cycle power to the Multichannel Media Converter by
disconnecting the power cord from the external AC outlet and
then reconnecting the power cord to the external AC outlet..
After a few seconds the start up screen comes up.
Management card configuration
-----------------------------------------------------
NETWORK PARAMETERS:
-------------------
IP address on LAN is 192.168.1.99
CONSOLE PARAMETERS:
-------------------
console channel will use a baud rate of 9600
BOARD PARAMETERS:
-----------------
Processor : MPC850, Running at 50Mhz
Board Info : Management Board
Board memory : FLASH : 4Mbytes
SDRAM : 4Mbytes
Board's Ethernet hardware address :
0:A0:D2:2F:80:82
-----------------------------------------------------
To change any of this, press any key within 5 seconds
6.
Immediately press any key in order to access the configuration
procedure. Type ‘m’ (or ‘M’) to modify the current settings.
The software then prompts with a series of default parameter values in
braces and a prompt either to press the ‘Return’ key to keep a displayed
parameter or to enter a new value.
2.12