Declaration of Conformity

Name of Mfg:

Transition Networks 
10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.

Model:

J/E-CF-02 Series Media Converters

Part Number(s):

J/E-CF-02,  J/E-CF-02(SC),  J/E-CF-02(SM)

Regulation:

EMC Directive 89/336/EEC; U.S.A. CFR

Purpose:  To declare that the

J/E-CF-02 to which this declaration refers is in

conformity with the following standards.

EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 subpart B; EN 61000-3-

2:2000; EN 61000-3-3:1995+A1:2001

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

April, 2007____

Stephen Anderson, Vice-President of Engineering

Date

2

24-hour Technical Support: 1-800-260-1312   Int’l: 00-1-952-941-7600 

[email protected] -- Click the “Transition Now” link for a live web chat.

7

J/E-CF-02

Installation 

Install the fiber cable 

1.

Locate a 10Base-FL fiber cable with male, two-stranded TX to RX
connectors installed at both ends.

2.

Connect the fiber cables to the J/E-CF-02 media converter as described: 

Connect the male TX cable connector to the female TX port.

Connect the male RX cable connector to the female RX port.

3.

Connect the fiber cables to the other device 

(another media converter,

hub, etc.)

as described: 

Connect the male TX cable connector to the female RX port.

Connect the male RX cable connector to the female TX port.

Install the copper cable 

Note:  

Connections between the J/E-CF-02 and a hub, or a switch require
straight-through cable.  Connections between the J/E-CF-02 and a
terminal, transceiver, router, or NIC require crossover cable cable.

(See page 4 for copper cable specifications.)  

Failure to observe this

caution will cause data transfer to fail.

1.

Locate or build 10Base-T copper cables with male, RJ-45 connectors
installed at both ends.

2.

Connect the RJ-45 connector at one end of the cable to the RJ-45 port on
the J/E-CF-02 media converter.

3.

Connect the RJ-45 connector at the other end of the cable to the RJ-45
port on the other device 

(switch, workstation, etc.).

Contact Us

Technical Support

Technical support is available 24 hours a day.
US and Canada:

1-800-260-1312

International:

00-1-952-941-7600

Transition Now

Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.

Web-Based Seminars

Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.

E-Mail

Ask a question anytime by sending an e-mail to our technical support staff.
[email protected]

Address

Transition Networks
10900 Red Circle Drive Minnetonka  MN  55343, U.S.A.
telephone:

952-941-7600

toll free:

800-526-9267

fax:

952-941-2322

Summary of Contents for J/E-CF-02(SC)

Page 1: ... der Benutzer für Gegenmaßnahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de créer des interférences radioélectriques il appartiendra alors à l utilsateur de prende les measures spécifiques appropriées Trademark Notice All trademarks and registered trademarks are the property of their respective owners Copyright Restrictions 2003 200...

Page 2: ...the male TX cable connector to the female RX port Connect the male RX cable connector to the female TX port Install the copper cable Note Connections between the J E CF 02 and a hub or a switch require straight through cable Connections between the J E CF 02 and a terminal transceiver router or NIC require crossover cable cable See page 4 for copper cable specifications Failure to observe this cau...

Page 3: ...erter fails isolate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the Pwr LED on the media converter illuminated NO Is the power adapter the proper type of voltage and cycle frequency for the AC outlet See Power Supply on page 5 Is the power adapter properly installed in the media converter and in the outlet Contact Technica...

Page 4: ... 3 Data Rate 10 Mb s Case Dimensions 3 9 x 3 0 x 1 0 99mm x 76mm x 25mm Weight 6 oz 181 g Power Consumption 2 8 watts 200 mA 13 9 VDC Power Supply 12VDC 0 5 Amp North America DC Output 12VDC 0 41 Amp Europe Japan Latin Am 12VDC 1 25 Amp UK Australia South Africa MTBF w power supply 53 077 hours MIL217F2 V5 0 MIL HDBK 217F 124 650 hours Bellcore7 V5 0 Environment Tmra 0 to 50 C 32 to 122 F Storage ...

Reviews: