5
J/E-CF-02
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber cable
Bit Error Rate:
<10-9
Single mode fiber
(recommended)
:
9 µm
Multimode fiber
(recommended)
:
62.5/125 µm
Multimode fiber
(optional):
100/140, 85/140, 50/125 µm
J/E-CF-02
850 nm multimode
Fiber Optic Transmitter Power:
min: -20.0 dBm
max: -10.0 dBm
Fiber Optic Receiver Sensitivity:
min: -32.5 dBm
max: -7.2 dBm
Link Budget:
12.5 dB
J/E-CF-02(SC)
850 nm multimode
Fiber Optic Transmitter Power:
min: -20.0 dBm
max: -10.0 dBm
Fiber Optic Receiver Sensitivity:
min: -32.5 dBm
max: -7.2 dBm
Link Budget:
12.5 dB
J/E-CF-02(SM)
1310 nm single mode
Fiber-optic Transmitter Power:
min: -23.0 dBm
max: -10.0 dBm
Fiber-optic Receiver Sensitivity:
min: -35.0 dBm
max: -14.0 dBm
Link Budget:
12.0 dB
Copper cable
Category 3
(minimum requirement)
Gauge
24 to 22 AWG
Attenuation
11.5 dB/100m @ 5-10 MHz
Maximum Cable Distance
100 meters
Category 5
(recommended)
Gauge:
24 to 22 AWG
Attenuation:
22.0 dB /100m @ 100 MHz
Maximum Cable Distance:
100 meters
• Straight-through OR crossover cable may be used (see below).
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Crossover Cable
1
2
3
6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6
Technical Specifications
For use with Transition Networks Model J/E-CF-02 or equivalent.
Standards
IEEE 802.3™
Data Rate
10 Mb/s
Case Dimensions
3.9" x 3.0" x 1.0"
(99mm x 76mm x 25mm)
Weight
6 oz.
(181 g)
Power Consumption
2.8 watts, 200 mA @ 13.9 VDC
Power Supply
12VDC, 0.5 Amp
(North America)
DC Output
12VDC, 0.41 Amp
(Europe, Japan, Latin Am.)
12VDC, 1.25 Amp (
UK, Australia, South Africa)
MTBF
(w/ power supply)
53,077 hours
(MIL217F2 V5.0)
(MIL-HDBK-217F)
124,650 hours
(Bellcore7 V5.0)
Environment
Tmra*:
0° to 50°C
(32° to 122°F )
Storage Temp:
-20° to 85°C
(-4° to 185°F)
Humidity:
5 to 95%, non condensing
Altitude:
0 to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature
The information in this user’s guide is subject to change. For the most up-to-date
information on the J/E-CF-02 media converter, view the user’s guide on-line at:
www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
WARNING: Visible and invisible laser radiation when open. Do not stare into
the beam or view the beam directly with optical instruments. Failure to observe
this warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation exposure.
CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB,
RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be
connected to intra-building
(inside plant)
link segments that are not subject to
lightening transients or power faults. Copper based media ports, e.g., Twisted
Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are
NOT to be connected to inter-building
(outside plant)
link segments that are
subject to lightening transients or power faults.
The fiber optic transmitters on this device meet Class I Laser safety requirements
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and
21CFR1040.11.
Use straight-through cable when
connecting to a hub or switch.
Use crossover cable when
connecting to a terminal,
transceiver, router, or NIC.