Constant Voltage DMX512 & RDM Decoder
Model No.: D1-CX / D2-CX / D3-CX / D4-CX / D5-CX
Subordinate New Brand
Features
Function Settings
Parameter
Model No.
Output
Total Output
Input Voltage
Input Signal
Connection
Working Temp.
Model No.
Output
Total Output
Input Voltage
Input Signal
Connection
Working Temp.
D1-CX
20A/Channel
D1-CX
20A/Channel
D2-CX
10A/Channel
D2-CX
10A/Channel
D3-CX
6A/Channel
D3-CX
6A/Channel
D4-CX
5A/Channel
D4-CX
5A/Channel
D5-CX
4A/Channel
D5-CX
4A/Channel
-20~60°C
-20~60°C
1. Accord with DMX512 standard protocol.
2. Digital Display, Set DMX initial address through button.
3. Support RDM function.
4. 2000hz/500hz Output PWM frequency is optional.
5. Logarithm/Linear dimming curve is optional.
6. Anti-reverse protection function
7. Short circuit&Overcurrent protection and recover function.
8. self-testing protection function when power on.
1.Digital Display status description
Self-locking:
Get into locking state when there is no operation over 30 seconds, digital
display with low light or OFF.
Unlock:
Long press M button 2 seconds to make digital display with high light, quit
self-locking state.
Address always ON:
DMX signal valid.
Address flickering:
DMX signal invaild.
Err:
Short circuit/overcurrent protection; self-recover after 10 seconds.
2. DMX initial address setting
Under unlock status, when digital display show 001-512( for example ), Short press
▲
button
or
▼
buttom, you can change the DMX initial address; Long press, you can change it quickly.
For Example: Set Initial address to 100
3. System Parameter Setting Instruction
Parameter 1: PWM frequency setting(show or ; Short press
▲
button or
▼
button to switch.
Under unlock status: Long press
M
button 3 seconds to make digital display show or ,
then get into system parameter setting. By this time, short press
M
button to switch 4 different
parameter setting circularly.
Set to PWM high frequency output, 2000Hz. (Factory default parameter)
Set to PWM low frequency output,500Hz.
Common anode
Max 20A
Max 20A
Max 18A
49mm
27mm
130mm
DC12~24V
DMX512, RDM
Parameter 2: Dimming Curve setting(Show or ), short press
▲
button or
▼
button to switch.
Dimming curve is logarithm dimming. (Factory default parameter)
Dimming curve is linear dimming.
Parameter 3: Dimming smoothness setting(show or ), short press
▲
button
or
▼
button to switch.
Smooth dimming. (Factory defaut setting)
Standard dimming.
Exit system mode: long press M button 1 second to exit. Or it will be self exit if there is no
operation over 8 seconds.
Parameter 4: Digital display showing setting(show or ) short press
▲
button
or
▼
button to switch.
Under self-locking status, digital display always ON (low lighting showing). (Factory
default parameter)
Under self-locking status, digital display OFF.
D1-CX
D2-CX
D3-CX
D4-CX
D5-CX
Occupy 1 address
100
Occupy 2 address
100-101
Occupy 3 address
100-102
Occupy 4 address
100-103
Occupy 5 address
100-104