Transition Networks E-TBT-FRL-1200 User Manual Download Page 3

CABLE SPECIFICATIONS

(continued)

COPPER CABLE 

Each RJ-45 connector requires 2 pairs of Category 5 rated cable.

The 50-pin Telco connector requires 24 pairs of Category 5 rated
cable.

Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can
be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation 

22.0 dB /100m @ 100 MHz

Maximum Cable Distance:

Telco

75 meters

RJ-45

100 meters

TELCO CONNECTOR

TELCO SIGNALS

Media Converter Port in Full-Duplex Network

In a full-duplex network, maximum cable lengths are determined by the
cables used. See page 10 for cable specifications. 

NOTE: The 5-Segment Rule described below does NOT apply in a full-
duplex network.

Media Converter Port in Half-Duplex Network

The 5-Segment Rule applies separately to each collision domain.

USING THE 5-SEGMENT (5-4-3) RULE:

NOTE: A segment is the cable connection between network interfaces. 

In any 10-Mbit/sec Ethernet collision domain, the 5-Segment Rule allows no
more than five segments. The 5-4-3 Rule version of the 5-Segment Rule
allows no more than five segments and also allows no more than four
repeaters (hubs) and three populated segments (10Base-2 coaxial-cable
installations). 

To determine the size of the collision domain by assigning segment numbers
to cable connections, determine the two network devices in a transmission
path that are separated by the greatest number of segments. Define a segment
path between the network devices by labeling the cable connection to the
first device “segment 1” and numbering each segment in the path to the last
network device, up to “segment n” (n = total number of segments  

5).

Verify that no segment path in the entire collision domain contains more than
n  

5 segments. 

E-TBT-FRL-xx

Port

Half-Duplex Collision Domain

Half-Duplex Collision Domain

Full-Duplex - NO Collision Domain

E-TBT-FRL-xx

Port

E-TBT-FRL-xx

Port

1

3

4

5

2

1

hub

hub

hub

hub

hub

hub

hub

3

4

2

10BASE-T/10BASE-FL Half-Duplex Collision Domain 

5-Segment Rule

Pin # Signal

Pin # Signal

1

Port 1 Transmit -

26

Port 1 Tr

2

Port 1 Receive -

27

Port 1 R

3

Port 2 Transmit -

28

Port 2 Tr

4

Port 2 Receive -

29

Port 2 R

5

Port 3 Transmit -

30

Port 3 Tr

6

Port 3 Receive -

31

Port 3 R

7

Port 4 Transmit -

32

Port 4 Tr

8

Port 4 Receive -

33

Port 4 R

9

Port 5 Transmit -

34

Port 5 Tr

10

Port 5 Receive -

35

Port 5 R

11

Port 6 Transmit -

36

Port 6 Tr

12

Port 6 Receive -

37

Port 6 R

13

Port 7 Transmit -

38

Port 7 Tr

14

Port 7 Receive -

39

Port 7 R

15

Port 8 Transmit -

40

Port 8 Tr

16

Port 8 Receive -

41

Port 8 R

17

Port 9 Transmit -

42

Port 9 Tr

18

Port 9 Receive -

43

Port 9 R

19

Port 10 Transmit -

44

Port 10 Tr

20

Port 10 Receive -

45

Port 10 R

21

Port 11 Transmit -

46

Port 11 Tr

22

Port 11 Receive -

47

Port 11 R

23

Port 12 Transmit -

48

Port 12 Tr

24

Port 12 Receive -

49

Port 12 R

25

N.C.

50

N.C.

1

25

26

50

Reviews: