E-TBT-FRL-xx00 IN THE NETWORK

Each media converter port in the multi-port media converter operates
independently over one isolated twisted-pair copper/fiber-optic cable
link. The media converter port receives and transmits network signals in
either full-duplex or half-duplex, depending upon the network devices
to which the media converter port is attached. 
NOTE: In Telco option (not shown), the 50-pin Telco connector
concentrates up to 12 UTP connections onto one connector. This
concentration of UTP ports is then broken out for connection to fiber.

RJ-45 CONNECTOR 

Twisted pair connection requires two active pairs configured as straight
through and/or crossover. The two active pairs in an Ethernet™ network are
pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white
& white/blue, orange/white & white/orange) for the active pins.

NOTE: The multi-port media converter AutoCross™ feature allows either straight-
through or crossover twisted-pair copper cable to be used when connecting to
10BASE-T devices. AutoCross™ determines the characteristics of cable
connections to the media converter port and then automatically configures the
port to link up.  

TECHNICAL SPECIFICATIONS

Standards

IEEE 802.3 1998 Edition

Case Dimensions

19.0" x 8.5" x 1.5"

(483 mm x 216 mm x 38 mm)

Environment

Temperature:

0-50°C (32° to 122° F )

Storage Temperature: -15° to 65°C (5° to 149° F )

Humidity

10-95%, non condensing 

Altitude

0-10,000 feet

Power 

100-240 VAC, 50/60 Hz., 1 Amp (maximum)

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

E-TBT-FRL-xx00, E-TEL-FRL-1200 Series Multi-Port Media Converter

Part Number(s):

E-TBT-FRL-0600,  E-TBT-FRL-0600(SC),  E-TBT-FRL-0600(SM),  
E-TBT-FRL-0600(L), E-TBT-FRL-0600(MT),  E-TBT-FRL-1200,  
E-TBT-FRL-1200(SC),  E-TBT-FRL-1200(SM), E-TBT-FRL-1200(L),  E-
TBT-FRL-1200(MT), E-TEL-FRL-1200,  E-TEL-FRL-1200(SC),  
E-TEL-FRL-1200(SM), E-TEL-FRL-1200(L),  E-TEL-FRL-1200(MT)

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the E-TBT-FRL-0600, E-TBT-FRL-1200 or E-TEL-FRL-

1200 to which this declaration refers is in conformity with the following
standards.

EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IE C 801.3, and IEC 801.4;  IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_November 3, 1999_____

Stephen Anderson, Vice-President of Engineering

Date

Switch

Hub

Switch

Hub

Server

Server

Full-Duplex

Full-Duplex

Half-Duplex

Half-Duplex

1

4

3

2

5

6

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

7

10

9

8

11

12

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

ACT

FBR LINK

TP LINK

POWER

Hub

Half-Duplex

Half-Duplex

Full-Duplex

Full-Duplex

Crossover 

1
2

3
6

Straight Through 

Twisted Pair #1

Twisted Pair #1

Twisted Pair #2

Twisted Pair #2

1
2

3
6

1
2

3
6

1
2

3
6