background image

8

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

CSDTF30xx-11x

Cable Specifications 

-- Continued

Fiber Cable -- Continued 

CSDTF3022-115

1310 nm single mode

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber Optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Link Budget:

10.0 dB

CSDTF3025-115

1310 nm single mode

Fiber-optic Transmitter Power:

min: -11.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -20.0 dBm

max: -3.0 dBm

Link Budget:

9.0 dB

CSDTF3027-115

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -15.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Link Budget:

13.5 dB

CSDTF3029-115

1310 nm (TX)/1550 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

CSDTF3029-116

1550 nm (TX /1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

CSDTF3029-117

1310 nm (TX)/1550 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

25.0 dB

CSDTF3029-118

1550 nm (TX)/1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

25.0 dB

The fiber optic transmitters on this device meet Class I Laser safety
requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10
and 21CFR1040.11.

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.

CAUTION: Visible and invisible laser radiation when open.  Do not stare into
the beam or view directly with optical instruments.

CAUTION: Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation exposure.

[email protected] -- Click the “Transition Now” link for a live Web chat.

9

Technical Specifications

For use with Transition Networks Model CSDTF30xx-11x or equivalent

Standards

Emissions: CISPR A; Telecordia TR-NWT-001089

(designed to meet; NOT tested)

; FCC Part 68; T1/E1

Physical layer: ITU-T, ANSI, AT&T, and ETSI; European
Technical Standard: TBR 12; British Technical
Publication: PD 7024 : 1994 

(NTR 4)

Dimensions

3.4" x 5" x 0.87" 

(86 mm x 182 mm x 22 mm)

Shipping Weight

3 oz.  

(91 g) 

approximately

Power Consumption

3.7 Watts

MTBF

478,901

(MIL217F2 V5.0) (MIL-HDBD-217F)

1,333,687 

(Bellcore7 V5.0)

Environment

Tmra*:

0 to 50°C 

(32° to 122° F )

Storage Temp:

-15° to 65°C 

(5° to 149°F)

Humidity:

5 to 95%, non condensing

Altitude:

0 to 10,000 feet

Warranty

Lifetime

*Manufacturer’s rated ambient temperature.  Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.  

The information in this user’s guide is subject to change.  For the most up-to-date
information on the CSDTF30xx-11x Device, view the user’s guide on-line at
www.transition.com.

Declaration of Conformity

Name of Mfg:

Transition Networks 

10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.

Model:

CSDTF30xx-11x Series Device

Part Number:

CSDTF3011-115, CSDTF3012-115, CSDTF3013-115, 
CSDTF3014-115, CSDTF3015-115, CSDTF3016-115, 
CSDTF3017-115, CSDTF3018-115, CSDTF3022-115, 
CSDTF3025-115, CSDTF3027-115, CSDTF3029-115, 
CSDTF3029-116, CSDTF3029-117, CSDTF3029-118

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the CSDTF30xx-11x to which this declaration refers is in

conformity with the following standards.

CISPR 22:1993; EN 55022:1998+A1:2000 Class A; EN 55024:1998; FCC Part 15 Subpart

B; EN 61000-3-2:1995+A14:2000: 61000-3-3:1995; CFR 21 Subpart J

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

July 2008     

Stephen Anderson, Vice-President of Engineering

Date

Summary of Contents for CSDTF3011-115

Page 1: ...8 ft SC 1310 nm single mode 60 km 37 3 miles CSDTF3017 115 75 ohm BNC coax 100 m 328 ft SC 1550 nm single mode 80 km 49 7 miles CSDTF3018 115 75 ohm BNC coax 100 m 328 ft MT RJ 1300 nm multimode 2 km 1 2 miles CSDTF3022 115 75 ohm BNC coax 100 m 328 ft ST 1310 nm single mode 15 km 9 3 miles CSDTF3025 115 75 ohm BNC coax 100 m 328 ft MT RJ 1310 nm single mode 20 km 12 4 miles User s Guide CSDTF30xx...

Page 2: ...ce mode is determined by the most recently saved on board microprocessor settings Hardware Mode Software Mode H H S S E1 Configuration switch 4 IMPORTANT Switch 4 MUST be set to the down position to set the Device for E1 configuration 1 2 3 4 E1 Configuration down Important techsupport transition com Click the Transition Now link for a live Web chat 3 Switch 2 Fiber Transmit All Ones Up Disables t...

Page 3: ...software control the network administrator can initiate the loop back test function on the coax interface local or remote or on the fiber interface local or remote CL FL techsupport transition com Click the Transition Now link for a live Web chat 5 Installation Continued Install the Copper Cable 1 Locate or build coax cables with female connectors installed at both ends 2 Connect the coax cables t...

Page 4: ...on the copper link when the fiber link is down local and or remote Power down the Device CSDTF30xx 11x 6 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 CSDTF COAX Fiber SDF SDC PWR TX RX RX TX CL FL techsupport transition com Click the Transition Now link for a live Web chat 7 Fiber Cable Single mode fiber recommended 9 µm Multimode fiber recommended 62 5 125 µm Multimode...

Page 5: ...pecified herein may result in hazardous radiation exposure techsupport transition com Click the Transition Now link for a live Web chat 9 Technical Specifications For use with Transition Networks Model CSDTF30xx 11x or equivalent Standards Emissions CISPR A Telecordia TR NWT 001089 designed to meet NOT tested FCC Part 68 T1 E1 Physical layer ITU T ANSI AT T and ETSI European Technical Standard TBR...

Page 6: ... mode enter the local copper loop back command and then use a bit error test unit to run a bit error test Verify the local fiber connection by starting a remote fiber loop back hardware mode set the loop back switch on the remote Device to FL software mode enter the remote fiber loop back command and then use a bit error test unit to run a bit error test Verify the remote copper connection by star...

Page 7: ...adian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause radi...

Reviews: