CSDTF30xx-11x

Install the Slide-in-Module 

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing the CSDTF30xx-11x slide-in-module Device.  Failure
to observe this caution could result in damage to, and subsequent failure of, the
Device.

1.

Locate an emply installation slot in the PointSystem™ chassis

2.

Carefully slide the slide-in-module into the installation slot, aligning the
module with the installation guides.  

3.

Ensure that the module is firmly seated inside the chassis.

4.

Push in and rotate the panel fastener screw clockwise to secure the module to
the chassis front.

 Media Converter

Point System Chassis

Panel Fastener

Slot

Installation 

-- Continued

Set the Loop-Back Switch 

Hardware Mode:

The loop-back switch is located on the front panel of the Device and is used for
installation and network debugging procedures.  

To set the switch, use a small flat-blade screwdriver or a similar device 

(see the

drawing to the right).

CL

(

Coax loop-back)

Enable loop-back on the local coax interface.

--

(Center position)

Normal operation.

FL

(Fiber loop-back)

Enable loop-back on the
local fiber interface.

Software Mode:

If both Devices are under software control, the network administrator can initiate
the loop-back test function on the coax interface 

(local or remote)

or on the fiber

interface 

(local or remote)

.

CL

FL

[email protected] -- Click the “Transition Now” link for a live Web chat.

5

Installation 

-- Continued

Install the Copper Cable

1.

Locate or build coax cables with female connectors installed at both ends.

2.

Connect the coax cables to the Device as described: 

Connect the female TX cable connector to the male TX port.

Connect the female RX cable connector to the male RX port.

3.

Connect the coax cables to the other device

(switch, workstation, etc.)

as

described: 

Connect the female TX cable connector to the male RX port.

Connect the female RX cable connector to the male TX port.

Install the Fiber Cable

1.

Locate or build fiber cable with male, two-stranded TX to RX connectors
installed at both ends.

2.

Connect the fiber cables to the local Device as described: 

Connect the male TX cable connector to the female TX port.

Connect the male RX cable connector to the female RX port.

3.

Connect the fiber cables to the remote Device as described: 

Connect the male TX cable connector to the female RX port.

Connect the male RX cable connector to the female TX port.

Connect fiber cable 
to media converter
as shown.

Connect fiber cable

to other device

(media converter, 

hub, etc.)

 as shown

RX

TX

RX

TX

Connect coax

cable to device

as shown

Connect coax
cable to other

device as shown

RX

TX

RX

TX

Summary of Contents for CSDTF3011-115

Page 1: ...8 ft SC 1310 nm single mode 60 km 37 3 miles CSDTF3017 115 75 ohm BNC coax 100 m 328 ft SC 1550 nm single mode 80 km 49 7 miles CSDTF3018 115 75 ohm BNC coax 100 m 328 ft MT RJ 1300 nm multimode 2 km 1 2 miles CSDTF3022 115 75 ohm BNC coax 100 m 328 ft ST 1310 nm single mode 15 km 9 3 miles CSDTF3025 115 75 ohm BNC coax 100 m 328 ft MT RJ 1310 nm single mode 20 km 12 4 miles User s Guide CSDTF30xx...

Page 2: ...ce mode is determined by the most recently saved on board microprocessor settings Hardware Mode Software Mode H H S S E1 Configuration switch 4 IMPORTANT Switch 4 MUST be set to the down position to set the Device for E1 configuration 1 2 3 4 E1 Configuration down Important techsupport transition com Click the Transition Now link for a live Web chat 3 Switch 2 Fiber Transmit All Ones Up Disables t...

Page 3: ...software control the network administrator can initiate the loop back test function on the coax interface local or remote or on the fiber interface local or remote CL FL techsupport transition com Click the Transition Now link for a live Web chat 5 Installation Continued Install the Copper Cable 1 Locate or build coax cables with female connectors installed at both ends 2 Connect the coax cables t...

Page 4: ...on the copper link when the fiber link is down local and or remote Power down the Device CSDTF30xx 11x 6 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 CSDTF COAX Fiber SDF SDC PWR TX RX RX TX CL FL techsupport transition com Click the Transition Now link for a live Web chat 7 Fiber Cable Single mode fiber recommended 9 µm Multimode fiber recommended 62 5 125 µm Multimode...

Page 5: ...pecified herein may result in hazardous radiation exposure techsupport transition com Click the Transition Now link for a live Web chat 9 Technical Specifications For use with Transition Networks Model CSDTF30xx 11x or equivalent Standards Emissions CISPR A Telecordia TR NWT 001089 designed to meet NOT tested FCC Part 68 T1 E1 Physical layer ITU T ANSI AT T and ETSI European Technical Standard TBR...

Page 6: ... mode enter the local copper loop back command and then use a bit error test unit to run a bit error test Verify the local fiber connection by starting a remote fiber loop back hardware mode set the loop back switch on the remote Device to FL software mode enter the remote fiber loop back command and then use a bit error test unit to run a bit error test Verify the remote copper connection by star...

Page 7: ...adian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause radi...

Reviews: