Installation
-- Continued
Install the Slide-In-Module
CAUTION:
Wear a grounding device and observe electrostatic discharge
precautions when installing the media converter.
Failure to observe this caution
could result in damage to, and subsequent failure of, the media converter.
To install the CRS4Fxxxx-100 media converter slide-in-module:
1.
Locate an empty installation slot on the
PointSystem™
Chassis.
2.
Carefully slide the slide-in-module into the installation slot, aligning the
module with the installation guides.
3.
Ensure that the module is firmly seated inside the chassis.
4.
Push in and rotate the attached panel fastener screw to secure the module
to the chassis front.
Install the Fiber Cable
1.
Locate or build fiber cable with male, two-stranded TX to RX connectors
installed at both ends.
2.
Connect the fiber cables to the CRS4Fxxxx-100 media converter as
described:
•
Connect the male
TX
cable connector the female
TX
port.
•
Connect the male
RX
cable connector to the female
RX
port.
3.
Connect the fiber cables to the other device (another media converter,
hub, etc.) as described:
•
Connect the male
TX
cable connector the female
RX
port.
•
Connect the male
RX
cable connector to the female
TX
port.
CFMFF100
CFMFF100
CETCF100
CFETF100
CFMFF100
SPD
PWR
FRX
CRX
FLNK
CLNK
10/100TX
RX
TX
10/100SX
100BASE-TX
RX
TX
100BASE-FX
Link Alert
E
D
0
50½
LA
PWR
RXF
RXC
LNK
COL
LKS
PWR
LKM
10BASE-2
10BASE-FL
LKS
PWR
LKM
LKS
PWR
LKM
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
I
0
TERM
INIT
RX
TX
LNK
PWR
CPSMM120
SERIAL
10BASE-T
R
E
S
E
T
I
0
Fiber
RS-232
RX
TX
P
CRS2F
Panel Fastener Screw
Connect the fiber cable
to the media converter
as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
-- Click the
“Transition Now”
link for a live Web chat.
5
Installation
-- Continued
Install the Copper Cable (DB-9 port)
Install the copper cable as instructed if the media converter has
a DB-9 copper port (CRS4F31xx-100 models).
NOTE:
Shielded RS-485/422 cables are required for EMC
compliance.
1.
Locate or build RS-485/422 cables with a female DB-9
connector on one end and a DB-9 connector that is
compatible with the other device on the other end of the
cable.
2.
Connect the female DB-9 connector at one end of cable to the male DB-
9 port on the CRS4F31xx-100 media converter.
3.
Connect the DB-9 connector at the other end of the cable to the DB-9
port on the other device.
Power the Media Converter
The media converter is powered through the
PointSystem™
chassis.
Install the Copper Cable (6-position terminal block)
Install the copper cable as instructed if the media converter has
a 6-position terminal block (CRS4F32xx-100 models).
NOTE:
Shielded RS-485/422 cables are required for EMC
compliance.
1.
Locate or build RS-485/422 cables with the six individual
wires stripped at both ends.
2.
Insert the individual wires at one end of cable into the six
terminal block ports on the CRS4F32xx-100 media converter.
3.
Insert the individual wires at the other end of the cable into the six
terminal block ports on the other device, matching the same color of
cable with the number of the port.
DB-9
X
CRS4F
2
6
3
4
5
1