Transition Networks 5250-CV-T-F/11 User Manual Download Page 3

Table of Contents

1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . 1

The 5250 Repeater  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Networking the 5250 Repeater  . . . . . . . . . . . . . . . . . . . . . . .2
Connectors, Switches, and Status Indicators  . . . . . . . . . . . . .3

2 SITE CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . 5

3 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Unpacking the 5250 Repeater  . . . . . . . . . . . . . . . . . . . . . . . .6
Connecting Host to Host 5250 Repeater  . . . . . . . . . . . . . . . .7
Connecting Host 5250 Repeater to Terminal 5250 Repeater  .9
Connecting Terminal 5250 Repeater to Terminal Equipment 11
Connecting Power to 5250 Repeaters  . . . . . . . . . . . . . . . . .13

4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . 16

Fault Isolation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Technical Support Contact  . . . . . . . . . . . . . . . . . . . . . . . . .12

WARRANTY STATEMENT

. . . . . . . . . . . . . . . . . . . . . . . . . . . 17

AS/400 & S/3x CABLE SPECIFICATIONS

. . . . . . . . . . . . . . 19

5250 REPEATER TECHNICAL SPECIFICATIONS

. . . . . . . . . 21

Twinax to Fiber

i

19

5250 Repeater

AS/400 & S/3x Cable Specifications

Twisted Pair Cable and Connector Specifications

The physical characteristics of the twisted pair cable must meet or exceed the
following:

Cable Characteristics: 

Category 3 wire or better is required; category 5 wire is recommended. Either
shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO
NOT USE FLAT OR SILVER SATIN WIRE.

Category 3:

Gauge

24 to 22 AWG

Attenuation 

28 dB/1000’ @ 10 MHz

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Category 5:

Gauge

24 to 22 AWG

Attenuation 

20 dB/1000’ @ 10 MHz

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Minimum Cable Distance:

Host to Product

7.6 meters (25 feet)

Product to Product

7.6 meters (25 feet)

Product to Terminal Device

7.6 meters (25 feet)

Maximum Cable Distance:

Host to Product

762 meters (2500 feet

)

Product to Product

762 meters (2500 feet

)

Product to Terminal Device

762 meters (2500 feet

)

Connector Characteristics:

Twisted pair connection requires one active pair configured as straight through. 

1

6

Top View
of the
RJ-11 Cable
Connector

1  2  3  4  5  6

Thick lines
indicate
pairs

Thin lines
indicate
pin leads

1

6

Crossview
of the RJ-11
Cable Connector

Top

1

8

RJ-45

 

J

ACK

1

8

2 3 4 5 6 7

When using RJ-11 connectors,
the active pair can be pins 2 & 5
or pins 3 & 4.

When using RJ-45 connectors,
the active pair can be pins 1 & 2,
pins 4 & 5 or pins 3 & 6.

Summary of Contents for 5250-CV-T-F/11

Page 1: ...1 6 165 mm x 105 mm x 41 mm Input Power Power Supply Adapter AC Input TN PN Requirement Location 3500 120 volts 60 hertz 28 watts USA Canada Mexico 3501 230 volts 50 hertz 28 watts Europe 3508 100 volts 50 60 hertz 28 watts Japan 3506 240 volts 50 hertz 28 watts United Kingdom 3510 240 volts 50 hertz 28 watts Australia DC Output 12 volts at 1 5 A maximum MTBF 45655 hours including power supply 525...

Page 2: ...ty of their respective owners Der Anschluss dieses Gerätes an ein öffentlickes Telekommunika tionsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität Twinax Cable...

Page 3: ...ther shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE FLAT OR SILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 28 dB 1000 10 MHz Differential Characteristic Impedance 100 Ω 10 10 MHz Category 5 Gauge 24 to 22 AWG Attenuation 20 dB 1000 10 MHz Differential Characteristic Impedance 100 Ω 10 10 MHz Minimum Cable Distance Host to Product 7 6 meters 25 feet Pro...

Page 4: ...d their installation to all persons and from all causes in the aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must f...

Page 5: ... NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS REGARDING SUCH PRODUCTS MADE BY TN ITS EMPLOYEES AGENTS OR REPRESENTATIVES B Limitations and Exclusions If the customer believes ...

Page 6: ... OUT 5250 CV T F 11 n e t w o r k s T R A N S I T I O N Mpls MN 55344 5 MAINTENANCE WARNING DO NOT UNDER ANY CIRCUMSTANCES open and attempt to repair the 5250 Repeater or power supply adapter unit Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation Technical Suppo...

Page 7: ...Fiber UTP Green Flashes rapidly during reception of valid 5250 packet from fiber or UTP connection Sync Twinax Green Flashes rapidly during reception of valid 5250 packet from twinax connection Error Fiber UTP Red Blinks at detection of parity error at fiber or UTP connection Error Twinax Red Blinks at detection of parity error at twinax connection Backup Active Red Illuminated when data reception...

Page 8: ...ply adapter To cascade 5250 Repeaters 1 Locate the Power OUT receptacle on first 5250 Repeater Pocket Hub 2 Connect one 5250 Repeater DIN cable connector to the 5250 Repeater Power OUT receptacle 3 Connect the other 5250 Repeater DIN cable connector to the Power IN receptacle of an adjacent 5250 Repeater 4 Connect second 5250 Repeater DIN cable connector to the adjacent 5250 Repeater Power OUT rec...

Page 9: ...tion in country where installed optional DIN cable 5070 for cascading up to four 5250 Repeaters to one power supply adapter User s Guide 7336 Additionally for unshielded twisted pair installations the installation requires Item Part Number baluns 3 4554 RJ 45 3 1143 RJ 11 Connecting Power to 5250 Repeaters NOTE After the power supply adapter is connected to the 5250 Repeater and to external power ...

Page 10: ...J 11 or RJ 45 plug connector to balun installed on terminal equipment twinax connector UTP Terminal 5250 Repeaters Connecting Host Signal to Host 5250 Repeater Connect the AS 400 S 3X or 5x94 host to the Host 5250 Repeater using either twinax cable or UTP cable and baluns Twinax Connection To connect twinax cable between AS 400 S 3X or 5x94 host and Host 5250 Repeater 1 Locate or build twinax cabl...

Page 11: ...ns See page 19 straight through cable configuration See page 5 male RJ 11 or RJ 45 plug connectors installed at both cable ends NOTE TRANSITION Network s part numbers for baluns are RJ 45 3 4554 RJ 11 3 1143 Twinax UTP Balun Connection To connect twisted pair cable between host and Host 5250 Repeater using twisted pair cables and baluns 1 Locate or build twisted pair cables with the following char...

Page 12: ... Repeater either to A or to B Optional UTP Backup Connection To connect twisted pair cable between Host 5250 Repeater and Terminal 5250 Repeater 1 Locate or build twisted pair cables with the following characteristics compliant with cable specifications See page 20 straight through cable configuration See page 5 male RJ 11 plug connectors installed at both cable ends 2 Connect male RJ 11 plug conn...