Transition Networks 5250-CV-T-F/11 User Manual Download Page 2

Twinax to Fiber

5250 Repeater

20

CAUTION:  RJ connectors are NOT INTENDED FOR
CONNECTION TO THE PUBLIC TELEPHONE
NETWORK. Failure to observe this caution could result
in damage to the public telephone network.

Compliance Information
UL Listed 
C-UL Listed (Canada)
CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class
A digital device, pursuant to part 15 of the FCC rules.  These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.  This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications.  Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the user
will be required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for
digital apparatus set out on the radio interference regulations of the Canadian
Department of Communications.

European Regulations
Warning

This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.

Copyright Restrictions

©  1996 TRANSITION Networks Inc.
All rights reserved.  No part of this work may be reproduced or used in any
form or by any means – graphic, electronic, or mechanical – without written
permission from TRANSITION Networks Inc.

Trademark Notice

All registered trademarks and trademarks are the property of their respective
owners.

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunika-
tionsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen
einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG
zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der
gegenseitigen Anerkennung ihrer Konformität. 

Twinax Cable and Connector Specifications

Cable Characteristics: 

Differential Characteristic Impedance 

100 

±10% @ 10 MHz 

Shielding:

Foil plus braid

Cable Type

IBM PN or equivalent

Twinax Plenum

7362061

Twinax PVC

7362211

Minimum Cable Distance:

Host to Product

7.6 meters (25 feet)

Product to Product

7.6 meters (25 feet)

Product to Terminal Device

not applicable

Maximum Cable Distance:

Host to Product

1500 meters (5,000 feet

)

Product to Product

1500 meters (5,000 feet

)

Product to Terminal Device

not applicable

Connector Characteristics:

Twinax connectors (IBM or equivalent) can be connected to twinax cable. (The
last twinax connection in a daisy-chain must be terminated.)

Fiber Cable and Connector Specifications

The physical characteristics of the fiber cable must meet or exceed the following:

Cable Characteristics: 

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

Average power:

-15.0 dBm

Peak power:-12.0 dBm ±1dBm

Fiber Optic Receiver Sensitivity:

Average sensitivity: -27.4 dBm

Bit error rate:

10

-10

Minimum Cable Distance:

Host to Product

7.6 meters (25 feet)

Product to Product

7.6 meters (25 feet)

Product to Terminal Device

not applicable

Maximum Cable Distance:

Host to Product

3000 meters (10,000 feet

)

Product to Product

3000 meters (10,000 feet

)

Product to Terminal Device

not applicable

Connector Characteristics:

ST type connectors (SMA type available upon request) 

Summary of Contents for 5250-CV-T-F/11

Page 1: ...1 6 165 mm x 105 mm x 41 mm Input Power Power Supply Adapter AC Input TN PN Requirement Location 3500 120 volts 60 hertz 28 watts USA Canada Mexico 3501 230 volts 50 hertz 28 watts Europe 3508 100 volts 50 60 hertz 28 watts Japan 3506 240 volts 50 hertz 28 watts United Kingdom 3510 240 volts 50 hertz 28 watts Australia DC Output 12 volts at 1 5 A maximum MTBF 45655 hours including power supply 525...

Page 2: ...ty of their respective owners Der Anschluss dieses Gerätes an ein öffentlickes Telekommunika tionsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität Twinax Cable...

Page 3: ...ther shielded twisted pair STP or unshielded twisted pair UTP can be used DO NOT USE FLAT OR SILVER SATIN WIRE Category 3 Gauge 24 to 22 AWG Attenuation 28 dB 1000 10 MHz Differential Characteristic Impedance 100 Ω 10 10 MHz Category 5 Gauge 24 to 22 AWG Attenuation 20 dB 1000 10 MHz Differential Characteristic Impedance 100 Ω 10 10 MHz Minimum Cable Distance Host to Product 7 6 meters 25 feet Pro...

Page 4: ...d their installation to all persons and from all causes in the aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must f...

Page 5: ... NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS REGARDING SUCH PRODUCTS MADE BY TN ITS EMPLOYEES AGENTS OR REPRESENTATIVES B Limitations and Exclusions If the customer believes ...

Page 6: ... OUT 5250 CV T F 11 n e t w o r k s T R A N S I T I O N Mpls MN 55344 5 MAINTENANCE WARNING DO NOT UNDER ANY CIRCUMSTANCES open and attempt to repair the 5250 Repeater or power supply adapter unit Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation Technical Suppo...

Page 7: ...Fiber UTP Green Flashes rapidly during reception of valid 5250 packet from fiber or UTP connection Sync Twinax Green Flashes rapidly during reception of valid 5250 packet from twinax connection Error Fiber UTP Red Blinks at detection of parity error at fiber or UTP connection Error Twinax Red Blinks at detection of parity error at twinax connection Backup Active Red Illuminated when data reception...

Page 8: ...ply adapter To cascade 5250 Repeaters 1 Locate the Power OUT receptacle on first 5250 Repeater Pocket Hub 2 Connect one 5250 Repeater DIN cable connector to the 5250 Repeater Power OUT receptacle 3 Connect the other 5250 Repeater DIN cable connector to the Power IN receptacle of an adjacent 5250 Repeater 4 Connect second 5250 Repeater DIN cable connector to the adjacent 5250 Repeater Power OUT rec...

Page 9: ...tion in country where installed optional DIN cable 5070 for cascading up to four 5250 Repeaters to one power supply adapter User s Guide 7336 Additionally for unshielded twisted pair installations the installation requires Item Part Number baluns 3 4554 RJ 45 3 1143 RJ 11 Connecting Power to 5250 Repeaters NOTE After the power supply adapter is connected to the 5250 Repeater and to external power ...

Page 10: ...J 11 or RJ 45 plug connector to balun installed on terminal equipment twinax connector UTP Terminal 5250 Repeaters Connecting Host Signal to Host 5250 Repeater Connect the AS 400 S 3X or 5x94 host to the Host 5250 Repeater using either twinax cable or UTP cable and baluns Twinax Connection To connect twinax cable between AS 400 S 3X or 5x94 host and Host 5250 Repeater 1 Locate or build twinax cabl...

Page 11: ...ns See page 19 straight through cable configuration See page 5 male RJ 11 or RJ 45 plug connectors installed at both cable ends NOTE TRANSITION Network s part numbers for baluns are RJ 45 3 4554 RJ 11 3 1143 Twinax UTP Balun Connection To connect twisted pair cable between host and Host 5250 Repeater using twisted pair cables and baluns 1 Locate or build twisted pair cables with the following char...

Page 12: ... Repeater either to A or to B Optional UTP Backup Connection To connect twisted pair cable between Host 5250 Repeater and Terminal 5250 Repeater 1 Locate or build twisted pair cables with the following characteristics compliant with cable specifications See page 20 straight through cable configuration See page 5 male RJ 11 plug connectors installed at both cable ends 2 Connect male RJ 11 plug conn...

Reviews: