Table 24 AI1422E Commands Listed Alphabetically
Command Name
Code
Reader Message
Set date
21
!Done
Set ECP timeout
NN = 01–FE (1–255)
timeout = 50 ms * NN
(if NN = FF, timeout is disabled)
612NN
!Done
Set reader ID number NN = 00–FF
60NN
!Done
Set RF attenuation NN = 00 to 0A)
644NN
!Done
Set RF timeout
N = 0–F (in milliseconds)
(always expired, 4,8,12,20,24,
32,48,60,92,152, 300,452,
600,752, infinite)
693N
!Done
Set RF timeout = infinite
693F
!Done
Set serial number
695S...S
!Done
Set time
20
!Done
Set uniqueness time-out to 15
seconds
442
!Done
Set uniqueness time-out to 2
minutes
441
!Done
Set uniqueness time-out to 30
seconds
443
!Done
Store hardware configuration
string
696S...S
!Done
Switch to command mode
01
Switch to data mode
00
!Done
Transmit all IDs
41
!Done
Turn off RF
640
!Done
Turn on RF
641
!Done
Turn RF off on timeout
6920
!Done
Turn RF off on timeout/no
presence
6922
!Done
Turn RF off on timeout/tag
6921
!Done
Use one stop bit
1010
!Done
Use two stop bits
1011
!Done
Appendix D Command Quick Reference
TransCore Proprietary
D–81