Table 17 Timeout Period Values
Command
Timeout (ms)
6939
92
693A
152
693B
300
693C
452
693D
600
693E
752
693F
Infinite (never expires, factory default)
Reader response:
!Done
or
!Error
The reader returns an Error message if a valid hexadecimal digit is not substituted for N in command
!
693N
.
695S...S Set Serial Number
!
695
assigns the reader serial number according to the format:
695SSSSSS
where
SSSSSS
is the serial number.
The serial number may contain as many as six uppercase or lowercase ASCII
alphanumeric characters.
Reader response:
!Done
Note: The factory-assigned serial number of the reader contains seven characters. However, to
maintain backward compatibility, the reader software allows only six characters to be entered.
When setting the serial number, skip the fourth (middle) character of the seven-character number
shown on the reader product label.
Once assigned, the serial number is preserved during power-down and the loading of default
parameters.
696S...S Store Hardware Configuration String
Command
!696S...S
stores hardware configuration information into reader memory.
The hardware configuration string is assigned according to the following format:
696S...S
where
S...S
is the hardware configuration string that may contain as many as 20
uppercase or lowercase ASCII alphanumeric characters.
AI1422E Reader User Guide
TransCore Proprietary
6–48