1.0” Solid State Disk
Transcend Information Inc.
V1.6
33
SMART Error Log.
ECC fail format:
(Log address
0xA0h
)
1 Byte
1 Byte
2 Byte
4 Byte
Count ECC fail Error Code Flash Block Address
LBA address
SMART Read Log
Command Code
B0h with the content of the Features register equal to D5h.
Input
The Features register shall be set to D5h.
The Sector Count register shall specify the number of sectors to be read from the log number
specified by the LBA Low register. It should specify 4. It can record 256 new bad blocks
information in this.
The LBA Mid register shall be set to 4Fh.
The LBA High register shall be set to C2h.
Log address definition
Log Address Content
R/W
00h
Log directory
RO
01h
Summary SMART error log
RO
06h
SMART self-test log
RO
A0h
Device vendor specific
VS
Note:
RO - Log is read only by the host.
R/W - Log is read or written by the host.
VS - Log is vendor specific thus read/write abiltiy is vendor specific.