16
3. The set-point value is activated and the display returns to the weighing mode.
Or
1. Press the NET/GROSS key.
The display shows the last entered value with the left digit blinking. The pointer for
set-point 1 is on.
2. Use the four directional keys to adjust the displayed value to the actual set point. In-
crease the flashing digit by pressing the UNITS key. Decrease the flashing digit by
pressing the ZERO/OFF key. Pressing the TARE key or the ON/PRINT key will
change the position of the flashing digit.
3. After entering the exact value, press the NET/GROSS key to save the value.
The pointer for set-point 2 is on.
4. After entering the exact value, press the NET/GROSS key to save the value.
The screen displays “SET” briefly.
The set-point value is activated and the display returns to the weighing mode.
The display shows TARE and the indicator automatically tares out the scale after the
scale has been stable for a few seconds.
Filling & Dosing:
1. The display shows the net value and the pointers stp1 and stp2 are on.
Relays 1 and 2 are closed.
2. As soon as set-point 1 is reached, pointer stp1 will turn off and relay 1 will be opened.
3. As soon as set-point 2 is reached, pointer stp2 will turn off and relay 2 will be opened.
4. The display shows “done” for a few seconds and then returns to the normal weighing
mode. The net weight is displayed. A printout may be made at this point.
Cancel the filling or dosing procedure at any time by pressing the NET/GROSS key (see
Cancelling the dosing or filling).
The printout will show the following:
-
The gross weight is the weight of the container with rest material.
-
The tare weight is the weight of the container with material before dosing.
-
The net weight will show a minus sign as token of weight being removed from the scale.
Cancelling the dosing or filling
Cancel the filling or dosing procedure at any time by pressing the NET/GROSS key.
1. Press the NET/GROSS key to stop the procedure.
The display shows “stop” and the relays are opened.
Pointers stp1 and stp2 will be turned off.
2. Press NET/GROSS to start the procedure again.
The display message “stop” is cleared and the net weight is displayed again.
The relays are closed. Pointers stp1 and/or stp2 will be turned on.
Or
1. Press the NET/GROSS key to stop the procedure.
The display shows “done” for a few seconds and will return in the normal weighing
mode.
The net weight is displayed.